7 | maintenance – GEA Bock HG5 R134a User Manual
Page 26

26
D
GB
F
E
96180-01.2015-DGbFEI
Refrigerants
GEA Bock standard oil types
Recommended alternatives
HFKW
(R134a)
Fuchs Reniso Triton SE 55
Fuchs Reniso Triton SEZ 32
Esso/Mobil EAL Arctic 46
Sunoco Suniso SL 46
Texaco Capella HFC 55
HGX5 / ... R134a
725-4
830-4
925-4
Designation
Ref. No.
Ref. No.
Ref. No.
Set of gaskets
08961
Valve plate kit
80719
Oil pump kit
08384
Oil sump heater kit
230 V ~
08426
Only use genuine GEA Bock spare parts!
7| Maintenance
7.3 Recommended spare parts
7.5 Extract from the lubricants table
The oil type filled as standard in the factory is marked on the
name plate. This oil type should be
used as a preference. Alternatives are stated in the extract from our lubricants table below.
Available accessories can be found on the Internet at www.gea.com
7.4 Accessories
7.6 Decommissioning
Close the shut-off valves on the compressor. Drain the refrigerant (it must not be discharged into the
environment) and dispose of it according to the regulations. When the compressor is depressurised,
undo the fastening screws of the shut-off valves. Remove the compressor using an appropriate hoist.