beautypg.com

8 | technical data – GEA Bock HG12Р User Manual

Page 22

background image

22

D
GB
F
E
I
Ru

09652-11.2014-DGbFEIRu

8| Technical data

Ty

pe

No.

of

cylin

-

ders

Displace

-

ment

50

/

60

Hz

(1450

/ 1740

rpm

)

Electrical data

W

eight

Co

nnec

tio

ns

Oil

charge

Sound pres

-

sure level

Voltage

Max.

Operating current

/ Y

Max.

power

consump

-

tion

Starting

current

(rotor

locked)

/ Y

Dis

-

charge

line

DV

Suction

line

SV

m

3

/h

A

kW

A

kg

m

m

(i

nc

h)

m

m

(i

nc

h)

Lt

r.

dB

(A

)

HG

12

P/

60

-4

S

2

5,

4 / 6

,4

6,

8 / 3

,9

2,

2

40 / 2

3

48

12

(

1

/

2

)

16

(

5

/

8

)

0,

8

58

,5 / 5

8 / 5

7

HG

12

P/

75

-4

6,

7 / 8

,1

7,1 / 4,1

2,3

40 / 2

3

48

59 / 5

8,

5 / 5

8

HG

12

P/

75

-4

S

6,

7 / 8

,1

8,

0 / 4

,6

2,6

43 / 2

5

49

59 / 5

8,

5 / 5

8

HG

12

P/

90

-4

8,

0 / 9

,6

8,

5 / 4

,9

2,8

43 / 2

5

49

59

,5 / 5

9 / 5

8

HG

12

P/

90

-4

S

8,

0 / 9

,6

8,

8 / 5

,1

2,9

45 / 2

6

49

59

,5 / 5

9 / 5

8

HG

12

P/

11

0-

4

9,

4 / 1

1,

3

9,

2 / 5

,3

3,1

43 / 2

5

49

60 / 5

9 / 5

8

HG

12

P/

11

0-

4 S

9,

4 / 1

1,

3

10

,6 / 6

,1

3,6

45 / 2

6

49

60 / 5

9 / 5

8

1

2

3

2

4

220-240 V

∆ / 380-420 V Y - 3 - 50 Hz

265-290 V

∆ / 440-480 V Y - 3 - 60 Hz

5

L / M / H

Tolerance

10%)

rela

tive

to

the

mean

value

of

the

volta

ge

range.

Other

volta

ges

and

types

of

current

on

request.

-

Th

e

sp

ec

ifi

ca

tio

ns

fo

r ma

x.

p

ow

er

c

on

su

m

pt

io

n

ap

pl

y

fo

r 5

0H

z

op

er

at

io

n.

Fo

r 6

0H

z

op

er

at

io

n,

th

e

sp

ec

ifi

ca

tio

ns

h

av

e

to

b

e

m

ul

tip

lie

d

by

th

e

fa

ct

or

1.

2. T

he ma

x. w

or

kin

g c

ur

re

nt r

ema

in

s u

nc

ha

ng

ed

.

-

Take account of the max.

opera

ting current / max.

po

wer consumption for

design

of

fuses,

supply

lines

and

safety

devices.

Fuse:

Consumption

ca

tegor

y AC3

1

2

All

specifica

tions

are

based

on

the

a

vera

ge

of

the

volta

ge

range

For solder connections

L

=

lo

w

tempera

ture

(-35

/

40

°C),

M

=

normal

cooling

(-10

/

45

°C),

H

=

air

conditioning

(5

/

50°C)

sound pressure level measured in

lo

w

reflection

measuring

area,

measuring

distance

1m.

Compressor

opera

tion

a

t 50

Hz

(1450

rpm),

refrigerant

R404A.

Values

sta

ted

are

a

vera

ge

values,

tolerance

±

2

dB(A).

5

3

4