Freerider FR168-4IT/Luggie User Manual
Page 38

incorrect installation of connectors when assembling the scooter after transporting
the scooter. If your Luggie scooter fails to operate refer to the status fault codes
on the following page for reference. If in doubt, consult the dealer from whom you
purchased your Luggie scooter.
DO NOT OPEN THE BATTERY HOUSING. BREAKING THE BATTERY SEAL
VOIDS THE WARRANTY AUTOMATICALLY!
SPEED CONTROLLER SETTINGS
Warning :
Performance adjustments should not be made to the wig wag levers
which could compromise the integrity of the speed controls and put the operator in
a serious danger. Performance adjustments should only be made by an Authorized
Luggie technician fully trained and conversant with the programming and capabilities
of the Luggie scooter.
Warning :
Incorrect settings could cause injury to the scooter operator and/or to
bystanders or damage to the scooter and/or surrounding property. If in doubt, consult
your Authorized Luggie Dealer.
37
STATUS FAULT CODES
FLASH
Description
Meaning
1
Battery Low
The battery is running low. Recharge the battery
2
Low Battery Fault
The battery has run out of charge. Recharge the
battery.
3
High Battery Fault
Battery voltage is too high. This may occur if
overcharged and/or traveling down a long slope.
When traveling down a slope, reduce your
speed to minimize the amount of regenerative
charge. Check the battery and associated
connections and wiring.
4
Current Limit Time-out
The motor has been exceeding its maximum
current rating for too long. This may be due to
a faulty motor. Check the motor and associated
connections and wiring. Turn the controller off.
Let it stand for a few minutes before powering it
back on again.