beautypg.com

Dark time doepfer, Functions 14, Pitch step-lenght ”1-8 combi – Doepfer Dark Time Sequencer User Manual

Page 14: Doepfer, Dark time

background image

Dark time

DOEPFER

Functions

14

3.1.6. Transport keys

These three keys control the so-called transport functions of Dark Time.

• Start/Stop key

Hitting the Start/Stop key once will get the sequencer going. Hitting it once

again, the sequencer will stop. The next hit will restart the sequence and play

back will continue from where it was stopped. In other words: If the sequence

was stopped on step 8, the sequence will continue from step 9 when hitting

Start/Stop.

• Reset key

Hitting the Reset key will reset the sequence to the first active step. This can

be step 1 (1-16 mode), step 1 and 9 (2x(1-8) mode) or any step in ”jump”

position which determines the current starting point of the sequence.

• Step key

The first hit will activate the Step key function. Each new hit on this key will

make the register skip one step forward to the next step available. This way

you can step through the sequence manually. Hitting the Stop key will quit

this

function.

Shuffle

Divide

Off

Jump

Jump

Jump

Jump

Jump

Jump

Jump

Jump

Off

Off

Off

Off

Off

Off

Off

Off

Jump

Jump

Jump

Jump

Jump

Jump

Jump

Jump

Off

Off

Off

0

0

2V

Scale

Random

Random

1-16

Off

Off

Off

Off

Stop

Stop

Stop

Stop

Stop

Stop

Stop

Stop

Stop

Stop

Stop

Stop

+1

6

1

-

9

6

1

-

9

Stop

Stop

Stop

Stop

Skip

Skip

Skip

Skip

Skip

Skip

Skip

Skip

Skip

Skip

Skip

Skip

1V

OffUp

Up

2x(1-8)

Internal

External

+1

8

-

1

8

-

1

Skip

Skip

Skip

Start/Stop Reset

Step

Function

Skip

On

On

On

On

On

On

On

On

On

On

On

On

5V

On

Down

Down

1-8

Combi

Midi/USB

-1

On

On

On

On

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

Cont.

-1

Cont.

Cont.

Cont.

Pulsewidth

Clock

Transpose

Range

Quantize

Direction

Link

Sync

Cont.

DARK TIME

DOEPFER

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

6

6

6

6

6

6

6

6

5

6

6

6

6

6

6

6

6

6

6

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

2

2

2

2

2

2

2

2

2

2

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

2

2

2

2

2

2

2

2

0

1

0

1

0

1

0

1

0

1

0

1

0

1

10

10

10

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

Pitch

Step-lenght

”1-8 Combi“

3.1.5. Individual gate length for steps 1 to 8:

As you already know, the

Pulsewidth control sets the gate time. This setting affects all steps by the same

factor. Now you will learn how to program individual gate time settings for each of the steps 1 to 8 (upper

register).

This function is enabled by the ”Custom” setting of the Link switch.

Set the

Link switch to ”Custom” position.

Simply turn the

step controls of the lower register to program individual gate time settings for the

corresponding steps of the upper register, e.g. use step pot 9 to adjust the gate time of step 1 and

so on. In this mode, the setting of the gate time is continuously variable, i. e. it is not dependent on

the clock divider settings.