beautypg.com

Dark energy doepfer, Functionality, Learn mode / midi functions – Doepfer Dark Energy I (device no longer available) User Manual

Page 21

background image

21

Dark EnerGy

DOEPFER

Functionality

3.3.3. Learn Mode / MIDI Functions

In learn mode you decide, how Dark Energy processes incomming MIDI data. Next to this, you control the

settings of the internal arpeggiator and set the reference tone, which determines the lowest note in Dark

Energy‘s note range.

You may access each function via MIDI program changes. The table below lists all functions. The notes (1)

to (10) explain all functions in detail.

Function

MIDI-Message

Count

1-128

Count

0-127

Note

Short Explanation

MIDI-Channel/Reference
note
(CV1=0V)

Note on

(1)

CV3 Velocity off

Program Change

#1

#0

(2)

CV3=Volume

CV3 Velocity on

Program Change

#2

#1

(2)

CV3=Volume*Velocity

CV4 Velocity off

Program Change

#3

#2

(2)

CV4=Ctr.X

CV4 Velocity on

Program Change

#3

#3

(2)

CV4=Ctr.X*Velocity

Retrigger

Off

Program Change

#5

#4

(3)

On

Program Change

#6

#5

(3)

Key-Assign-Mode

Highest note

Program Change

#15

#14

(6)

Last note

Program Change

#16

#15

(6)

Reference note

Program Change

#17

#16

(6)

Stack note

Program Change

#18

#17

(6)

Arp. Mode On/Off

Program Change

#19

#18

(7)

Arpeggiator

Arp. Mode Hold

Program Change

#20

#19

(7)

Arpeggiator

Arp. Mode Overwrite

Program Change

#21

#20

(7)

Arpeggiator

Arpeggiator Sync -
Internal

Program Change

#22

#21

(8)

Tempo - internal

Arpeggiator Sync –
External (MIDI
Realtime/Clock)

Program Change

#23

#22

(9)

Tempo - external

Controller for CV4

Free MIDI-
Controller (not
Bank Change-
Controller
Ctrl-0/32)




(10)

Notes:

(1) MIDI channel/reference for CV1=0V

In case of an incoming note event in the learn mode the note number and the channel of the event are ta-

ken over as the new reference tone and MIDI channel of Dark Energy. The reference note is the MIDI note

number that belongs to 0V CV1 output. In practice you simply enter the learn mode and press the key on

your MIDI keyboard that should belong to 0V CV1. MIDI note events below the reference note or more than

5 octaves above the reference note are ignored as the CV1 voltage range of Dark Energy is 0...+5V. The

factory default settings of reference note and MIDI channel are note number 36 (C) and channel 1.