1.0 I

NTRODUCTION

Congratulations on your purchase of a Checkline

®

LS-5-RCU Remote Control

Unit for Linear Stroboscope. The LS-5-RCU provides and easy-to-use control
center for any stroboscope whether it is from Electromatic or other manufac-
turers. Use it to create a trigger signal or to influence a signal generated exter-
nally. The multiplicity of control parameters make it easy for you to carry out
the inspection or measurement tasks required of you.

NOTE: When using a stroboscope, remember that while objects may appear
to become motionless, they are, in fact, still moving. Exercise proper care to
prevent injury.

Please read this instruction manual thoroughly before operating your remote
control unit. If you have any questions not answered by this manual, call your
local supplier, or visit our web chat interface at www.checkline.com for full
product support.

1.1 Package Contents

The LS-5-RCU Remote Control Unity is
shipped fully assembled in a hard-plastic
carrying case. Your package should contain
the following:

• LS-5-RCU Remote Control Unit
• Trigger cable (1.5m)
• Operating

instructions

• Certificate
• Case

After unpacking, please examine your control unit for signs of mishandling
during shipping. If damage has occurred, contact Electromatic before attempt-
ing to plug in the instrument. Notify your shipping carrier immediately for
damage claim instructions.

2.0 S

AFETY

• When using a stroboscope, remember that objects may appear to

become motionless, but they are still moving. Exercise proper care
to prevent injury.

• Do not look directly at the emitted light from a stroboscope; it can

damage your eyes. It may trigger seizures in people with epilepsy.

• The LS-5-RCU must not be used in explosion hazard areas.

• Store the LS-5-RCU in dry conditions.

- 11 -

8.0 D

EFAULT

P

ARAMETER

S

ETTINGS

The default values for the strobe control settings are listed below: for the

Internal Trigger

FPM

1000

• Hz

16.6

• PULSE μs

333

PULSE deg 2°

• DELAY ms

0 . 0

• PHASE deg. 0°

• DIVIDER 1

• OPTION 0