SYMPTOM
PROBABLE CAUSE
ITEMS TO EXAMINE OR CORRECT
Charge OFF at high
ambient temperature
System temporarily shuts down due to
high heat sink temperature
Improve ventilation or reduce PV power. Sufficient ventilation to prevent over
temperature shut down will improve reliability. See Technical Bulletin #100206.
When charger turns
on, output current
displays but the
value seems
incorrect
Output current display selection set for
wrong IPN network address
Bat– connected to PV– outside charge
controller
Configure display IPN network address DIP switch to read desired output current.
PV- & BAT- must be separate external to the unit for proper operation and cannot
connect to a common location. External connection prevents proper operation of
internal shunts and current measurement system.
Voltage or current
value displayed
seems to be stuck
and does not change
Display or charge controller IPN network
addressed has changed
Display not communicating with charge
controller
Configure display IPN network address DIP switch to properly read output current
of a charger present on the IPN network
Intermittent display cable.
SPECIFICATIONS
SPECIFICATIONS
Solar Boost 3024iL & 3024DiL
Output Current Rating
30A / 40A
ℜ
Nominal Battery Voltage
12 / 24VDC
PV Input Voltage
57VDC maximum
Power Consumption
Typical 0.35W standby
• 1.0W Charge ON
Charge Algorithm
3-stage Bulk/Acceptance/Float
• plus Equalize
Acceptance Voltage
14.4VDC
ℵ
(range 14.0 – 14.8VDC
ℵ
, 10.0 – 40.0VDC
ℑ
)
Float Voltage
13.2VDC
ℵ
(range 13.2 – 13.8VDC
ℵ
, 10.0 – 40.0VDC
ℑ
)
Equalization Voltage
15.2VDC
ℵ
(range 10.0 – 40.0VDC
ℑ
)
• automatic or manual
Voltage Setpoint Limit
15.5VDC
ℵ
(range 10.0 – 40.0VDC
ℑ
)
Single output configurable as either: 20A load controller –or– 2A auxiliary battery charger
2A typical, same charge voltage as primary battery
20A maximum, ON ≥12.6VDC
ℵ
/ OFF ≤11.5VDC
ℵ
(Range 10.0 – 40.0VDC
ℑ
, or net battery AH
ℑ
)
Auxiliary Output
• Aux. Battery Charge
• Load Control
• Dusk-to-Dawn Control
ℑ
Variable Post–Dusk and Pre–Dawn timers
ℑ
, Range 0.5 – 20.0 hours
Temperature Compensation
Optional sensor adjusts charge voltage based on battery temperature
–5.00 mV/
°C/cell correction factor (Range 0.00 to –8.00 mV/°C/cell
ℑ
)
• sensor range –60 to +80°C
Power Conversion Efficiency
97% typical @ 28V / 24A Output
Cabinet Dimensions
6⅞”H x 6⅝”W x 3⅜”D (17.4cm x 16.8cm x 8.59cm)
Volt/Amp Accuracy/Range
Battery voltmeters 40.0VDC
±0.50% FS • PV voltmeter 60.0VDC±0.50% FS
Ammeters 41.0A
±0.50% FS
Communication
Blue Sky Energy’s proprietary IPN Network interface
Environmental
–40 to +40
°C, 10 – 90% RH non-condensing
As a part of our continuous improvement process
ℵ
SB3024i alone, voltages double for 24V battery
specifications are subject to change without prior notice
ℑ
With IPN-ProRemote
ℜ