beautypg.com

Specifications – Blue Sky Solar Boost 3024iL User Manual

Page 15

background image

Installation and Operation Manual

14

SYMPTOM

PROBABLE CAUSE

ITEMS TO EXAMINE OR CORRECT

Charge OFF at high
ambient temperature

System temporarily shuts down due to
high heat sink temperature

Improve ventilation or reduce PV power. Sufficient ventilation to prevent over
temperature shut down will improve reliability. See Technical Bulletin #100206.

When charger turns
on, output current
displays but the
value seems
incorrect

Output current display selection set for
wrong IPN network address

Bat– connected to PV– outside charge
controller

Configure display IPN network address DIP switch to read desired output current.

PV- & BAT- must be separate external to the unit for proper operation and cannot
connect to a common location. External connection prevents proper operation of
internal shunts and current measurement system.

Voltage or current
value displayed
seems to be stuck
and does not change

Display or charge controller IPN network
addressed has changed

Display not communicating with charge
controller

Configure display IPN network address DIP switch to properly read output current
of a charger present on the IPN network

Intermittent display cable.

SPECIFICATIONS

SPECIFICATIONS

Solar Boost 3024iL & 3024DiL

Output Current Rating

30A / 40A

Nominal Battery Voltage

12 / 24VDC

PV Input Voltage

57VDC maximum

Power Consumption

Typical 0.35W standby

• 1.0W Charge ON

Charge Algorithm

3-stage Bulk/Acceptance/Float

• plus Equalize

Acceptance Voltage

14.4VDC

(range 14.0 – 14.8VDC

, 10.0 – 40.0VDC

)

Float Voltage

13.2VDC

(range 13.2 – 13.8VDC

, 10.0 – 40.0VDC

)

Equalization Voltage

15.2VDC

(range 10.0 – 40.0VDC

)

• automatic or manual

Voltage Setpoint Limit

15.5VDC

(range 10.0 – 40.0VDC

)

Single output configurable as either: 20A load controller –or– 2A auxiliary battery charger

2A typical, same charge voltage as primary battery

20A maximum, ON ≥12.6VDC

/ OFF ≤11.5VDC

(Range 10.0 – 40.0VDC

, or net battery AH

)

Auxiliary Output

• Aux. Battery Charge

• Load Control

• Dusk-to-Dawn Control

Variable Post–Dusk and Pre–Dawn timers

, Range 0.5 – 20.0 hours

Temperature Compensation

Optional sensor adjusts charge voltage based on battery temperature

–5.00 mV/

°C/cell correction factor (Range 0.00 to –8.00 mV/°C/cell

)

• sensor range –60 to +80°C

Power Conversion Efficiency

97% typical @ 28V / 24A Output

Cabinet Dimensions

6⅞”H x 6⅝”W x 3⅜”D (17.4cm x 16.8cm x 8.59cm)

Volt/Amp Accuracy/Range

Battery voltmeters 40.0VDC

±0.50% FS • PV voltmeter 60.0VDC±0.50% FS

Ammeters 41.0A

±0.50% FS

Communication

Blue Sky Energy’s proprietary IPN Network interface

Environmental

–40 to +40

°C, 10 – 90% RH non-condensing

As a part of our continuous improvement process

SB3024i alone, voltages double for 24V battery

specifications are subject to change without prior notice

With IPN-ProRemote

40A with 12V battery and 12V PV modules