beautypg.com

2 physical specifications, 3 regulatory information, Physical specifications – Windy Nation TrakMax 40 MPPT Solar Charge Controller User Manual

Page 6: Regulatory information

background image

TrakMax 40 User Manual

Revision 1.0

Overload Protection (DC load)

2.0*Inom>5s

1.5*Inom >20s

1.25*Inom temperature controlled

Bulk Charge (adjustable)

14.6V(default)

29.2V(default)

Floating Charge (adjustable)

13.4V(default)

26.8V(default)

Equalization Charge

14.0V(default)

28.0V(default)

Overcharge Disconnection

14.8V

29.6V

Overcharge Recovery

13.6V

27.2V

Over-discharge Disconnection

10.8 V (default)

21.6V(default)

Over-discharge Reconnection

12.3V

24.6V

Temperature Compensation

-13.2mV/

o

C

-26.4mV/

o

C

Lead Acid Battery Settings

Adjustable

NiCad Battery Settings

Adjustable

Load Control Mode

1. Low Voltage Reconnect (LVR)
2. Low Voltage Disconnect (LVD): Auto disconnect

Low Voltage Reconnect

12.0-14.0 VDC

24.0-28.0 VDC

Low Voltage Disconnect

10.5-12.5 VDC

21.0-25.0 VDC

Ambient Temperature

0 – 40

o

C (full load) 40 – 60

o

C (de-rating)

Altitude

Operating 5000 m, Non-Operating 16000 m

Enclosure Protection Class

IP21

Battery Temperature Sensor
(BTS)

Optional remote sensor increases charging precision

Terminal Size (fine/single wire)

Maximum 6 AWG

NOTE: The optional battery temperature sensor automatically adjusts the charging process of the controller
according to the type of battery selected by the user. With the battery temperature sensor installed, the
controller will increase or decrease the battery charging voltage depending on the temperature of the battery
to optimize the charge to the battery and to maintain battery performance.

2.2.2

Physical Specifications

Parameter

Value

Dimension (H x W x D)

7.56” (192mm) x 5.51” (140mm) x 2.6” (66mm)

Unit Weight

3.1 lb. (1.4Kg)

Mounting

Vertical wall mount - indoor only

Cooling

Natural cooling

Operating Temperature

0

o

C to 40

o

C (40

o

C to 60

o

C de-rating)

Storage Temperature

-25

o

C to 70

o

C

Operating Humidity

20 to 80% relative humidity (non-condensing)

Non-Operating Humidity

Greater than 95% relative humidity

38.7

o

C max wet bulb temperature with no damage

2.2.3

Regulatory Information

The TrakMax has safety approvals as follows:

• UL 1741

• FCC Part 15B
• EN61000-6-3:2001

• EN61000-6-1:2001
• EN 60335-1


FCC Requirements:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

Page 6 of 20