Typical system wiring diagram - four pole, Impor t ant, Comfort control relay panel (ccrp) page 9 – Steffes Comfort Control Relay Panel (CCRP) User Manual
Page 12: Op ti o n, Si ngl e fe ed
Comfort Control Relay Panel (CCRP)
Page 9
TYPICAL SYSTEM WIRING DIAGRAM - FOUR POLE
(Utilizing PLC Control with the Steffes 1000/2000/2100 Series Room Units)
Is
B
ein
g
U
til
iz
e
d
B
y
P
E
A
K
CO
N
T
RO
L
R
LO
W
V
O
L
TA
G
E
CO
N
N
E
C
T
IO
N
S
O
v
er
ride
M
o
dul
e
(O
P
T
IO
NA
L)
OS
OS
SW
IT
C
H
UT
IL
IT
Y
PE
A
K
C
O
N
T
R
O
L
SW
IT
C
H
in
th
e CCRP
.)
T
er
m
in
al
B
lock
O
v
er
ride
C
o
m
m
on
C
ir
cui
t 4 O
v
er
ride
Ci
rcuits
2
& 3 Ov
err
ide
C
ircu
it 1
O
v
e
rri
d
e
CO
R
PO
R
A
TI
O
N
ST
E
FFE
S
Ov
er
rid
e Ho
t
O
v
e
rri
d
e S
w
itc
h
CI
RC
UI
T 3
C
E
A
P
S
E
NS
OR
(O
P
T
IONAL
)
Th
e P
o
w
er
C
o
m
p
an
y
.
RE
M
O
TE
O
U
T
D
OOR
CI
RC
U
IT 1
(S
EE N
O
T
E
1
)
CI
R
C
UI
T 2
OV3
L
O
W VOL
T
A
G
E
C
ONNE
C
T
IO
N
S
OV1
OV2
OV4
OVS
OVR
OVC
th
e Re
la
y
s a
n
d
th
e F
act
or
y t
o
C
o
n
n
ect
ed
at
(T
hi
s E
nd
is
W
ir
e L
eads.
F
act
or
y
I
n
st
al
le
d
CI
RC
U
IT 4
(2
0
Am
p
Circ
u
it M
ax
im
u
m
)
(3
0
Am
p
Circ
u
it M
ax
im
u
m
)
T
O
C
ONT
ROL
L
E
D
L
OAD
TO
CO
N
T
R
O
L
LED
L
O
A
D
(S
ee
N
o
te 3)
Wi
rin
g
Insta
lle
d
Fi
el
d
ROOM
TEM
P
E
RA
TU
RE
S
ET BA
CK
UT
IL
IT
Y
A
N
T
IC
IP
A
TED
R
o
om
T
em
p
e
ra
tur
e
S
et B
ac
k
i
s O
p
ti
o
n
al
O
n
ly if
A
n
ti
ci
p
a
te
d
P
ea
k
C
IR
C
UI
T ONE
20 A
M
P
MA
X
OP
TI
O
N
A
R
E
D
C
IR
C
U
IT
.
R
ed C
ir
cui
t 2
T
Y
P
IC
A
L
SU
PP
LY
Re
d
C
ir
cu
it 1
Bla
ck
Circ
u
it 1
Bla
ck
Circ
u
it 2
CI
R
C
UITS
5
4
3
2
1
10
9
8
7
240V
AC
S
OUR
C
E
6
BL
U
E
BL
U
E
BL
A
C
K
GR
E
E
N
D
UAL
OP
TI
O
N
F
EED
BL
A
C
K
RE
D
RE
D
GR
E
E
N
BL
U
E
BL
A
C
K
BL
U
E
BL
A
C
K
RE
D
RE
D
S
Y
S
T
E
M
GR
OUN
D
(S
EE N
O
T
E
2
)
NO
T
E
:
M
O
D
E
L
S
2
002
A
N
D
2
0
0
3
DO
NO
T
HA
VE
SI
NGL
E
FE
ED
CI
RCUI
T
2
CI
RC
U
IT 3
CI
RC
U
IT 1
CI
R
C
U
IT
4
A panel label is provided in the package of
screws used to mount the front panel. Apply
this label to the service panel to identify the
breaker feeding CCRP circuit 1.
IMPOR
T
ANT
1.
Loads connected between L1 and L2 on circuit 1 will be uninterrupted. Loads con-
nected between T1 and L2 on circuit 1 will be interrupted. CCRP circuit 1 feeds both
output circuit 1 and the panels internal controls. Maximum fuse size is 20 amps.
2.
The system grounding and bonding must be sized and installed in compliance with all
applicable codes.
3.
Any loads requiring greater than a 20 amp circuit, such as a water heater
, must never
be connected to circuit 1 in the CCRP as circuit 1 is only capable of controlling a
maximum of a 20 amp circuit.