Local path, On path – Vermont Casting DV580 User Manual
Page 37
37
DV360/580 Series Direct Vent Gas Fireplace
20010667
Comfort Valve System Control Sequence of Operation with Transmitter
Light pilot burner
Set manual switch
to local or remote
Release pilotstat
knob
Turn pilotstat knob
from PILOT to ON
If manual switch is
set to LOCAL, did
main burner light?
Transmitter con-
trols fan
Turn pilotstat knob
to PILOT to turn
off main burner
Turn pilotstat knob
to OFF to turn
valve completely
off
Did the LED stop
blinking?
Review LED fail-
ure analysis
Five minute wait
period
Cycle switch
once and leave in
remote. Press any
key on transmit-
ter for recognition
operation
Local Path
Move switch from
local to remote.
Press any key on
transmitter. Move
switch back to
local
Yes
Yes
If the manual switch
is set to REMOTE,
press the mode but-
ton to display “ON”.
Does transmitter con-
trol the main burner
and fan?
Does transmitter
change levels of
flame height, fan
speed and set
temperature?
Set levels of flame
height and fan to
“0” to shut off main
burner and fan
Turn pilotstat knob
to OFF to turn
valve completely
off
On Path
Move switch from
manual to remote.
Press any key on
transmitter.
Yes
Yes
No
No
Choose Local or
Remote path. Set
switch to manual or
remote
Yes
Yes