Panasonic WV-7230D User Manual
Page 8
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
C. Wiring with the Connection Cable (WV-CA50)
The appearance and cord length is shown in the drawing.
The parts name of WV-CA50 is shown in the following.
No.
Parts name
1
18 wires cable
2
14P housing
3
12P housing
4
10P housing
5
8P housing
6
Contact
7
BNC connector
The wire gauge can be determined by the chart below.
• The system should be operated by 24V AC and the
power consumption should have less than 11W for the
camera.
Model
WV-7230D
Copper wire gauge AWG No.
Cable length
AWG size
Impedance
(fì/km)
11
13
#24
77.9
ft
30
65
m
10
15
#22
50.4
ft
50
100
m
15
30
#20
32.3
ft
80
155
m
20
45
#18
19.9
ft
130
250
m
40
70
• Cable assembly:
Strip back the cable jacket approx. 0.1 inch and
separate the individual conductors.
D. In case of using the accessory connectors
(MX5557P08 and MX5S57P10)
Select a multi-conductor cable which meets FR-1 rating
with 11 or 13 wires cables for WV-7230D.
12 wires cable is used to extend the cable lengt^
Connect the 11 or 13 wires cable to the following positions
of the accessory connectora
CN Pin No.
WV-7230D
Usage of Terminal
Power Source
CN1-1
LEFT
24 V AC
CN1-2
RIGHT
CN1-3
UP
CN1-4
Down
CN2-1
24V AC Camera
CN2-5{6)(7)
AC Common
CN1-7
DC COMMON
24V AC Common
CN1-8
Iris Control
±6V DC Common
CN1-9
Focus Control
±6V DC
CN1-10
Zoom Control
CN2-8
Camera Ground
• If 13 wires cable are available for WV-7230D, connect
the remainded 2 wires to the ( ) positioa
1
1
10
9 £
П 7
6
5
4 ;
П 2
1
8
7 6
5
4 3
2
1
CN1
CNZ
The accessory connectors view from wiring side.
Contact
Up >
^^3
Approx.
0.1 inch
Wire
2
^ Insert
Insert the wire until A position
and clamp the contacts.
Preparate the individual cortductors for clamping.
If clamping, use MOLEX brand tool part number
57027-5000 (for UL-Style Cable UL1015 or
57026-5000 (for UL-Style cable UL1007).
After clamping the contacts, push them into the proper
holes in the connector housing until they snap in place.
Up
Î
Wire
Contact
CAUTIONS:
Shrinking the cable-entry seal is a one-time procedure.
DO NOT shrink the cable-entry seal until it has been
ascertained that the unit is functioning.
CONNECT THIS TO 24V AC CLASS 2 POWER SUPPLY
ONLY.
Caution:
To prevent fire or shock hazard,
the UL listed wire VW-1, style 1007
should be used for the cable for 24V
AC Input Terminals.
-
7
-