beautypg.com

Appendix, Timer, Message codes – Leica Geosystems Leica DISTO A8 User Manual

Page 12

background image

9

Appendix

Leica DISTO™ A8 1.1.0 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

RC

ROK

PL

H

RUS

CZ

be adjusted with the PLUS - key {A, 3} or MINUS -
key {A, 11}. Through pressing the EQUAL - key {A, 5}
again the adjustment is confirmed. Now the value can
be stored as usual as a constant.

Historical Storage

Press STORAGE - key {A, 7} twice quickly and the
previous 30 results (measurements or calculated
results) are shown in reverse order. Using the PLUS -
key {A, 3} and the MINUS - key {A, 11} allows to
navigate in the historical storage. Press EQUAL - key
{A, 5} to take a result from the historical storage to
use for further calculations.

Timer

Press and hold TIMER - key {A, 4} until desired time
delay has been reached (5 - 60 seconds).
Press DIST - key {A, 1}. Once the key is released the
remaining seconds until measurement are displayed.
The last 5 seconds are counted down with a beep.
After the last beep the measurement is taken.

Appendix

Message Codes

All message codes will be displayed with either "InFo"
or "Error".

The following mistakes can be corrected:

InFo

Cause

Remedy

154

Transverse tilt < 20° Hold the instrument

without any trans-
verse tilt

204

Calculation error

Repeat procedure

206

No endpiece detec-
tion

Attach the endpiece
properly. If error still
occurs, replace the
endpiece.

252

Temperature too
high

Cool down instrument

253

Temperatur too low Warm up instrument

255

Receiver signal too
weak, measurement
time too long,
distance > 100 m

Use target plate

256

Received signal too
powerful

Use target plate
(grey side)

257

Wrong measure-
ment, ambient
brightness too high

Use target plate
(brown side)

260

Laser beam inter-
rupted

Repeat measurement

Error

Cause

Remedy

Hardware error

Switch on/off the
device several times
and check if the
symbol still appears. If
so please call your
dealer for assistance.