Model 1050 standalone enclosure user manual, Installing and using the 1050 enclosure, Specifications – CANOGA PERKINS 1050 Standalone Enclosure User Manual
Page 3

EdgeAccess Model 1050
3
Model 1050 Standalone Enclosure User Manual
The Model 1050 standalone enclosure, shown in Figure 1, supports one 5U-sized, unmanaged
module.
Figure 1. Model 1050 Standalone Enclosure
The front provides a slot for a module. The back includes an AC power cord socket. The AC power
supply provides +5 VDC to the module.
Installing and Using the 1050 Enclosure
To use the 1050 enclosure:
1. Place it on a secure surface with room for air flow and within 7 ft. (2.134 m) of the AC power
source.
2. Insert a module in the guide rails and press it firmly into the backplane, then secure the
thumbscrews finger-tight.
3. Plug the power cord into the rear of the 1050 enclosure, then plug it into the AC power source;
this turns on the power. To turn off the power, unplug the power cord.
4. To use the module in the 1050 enclosure, see the Users Manual for the module.
Specifications
Dimensions:
11.70"L x 12.0"W x 1.718"H (297 mm x 305 mm x 44 mm)
Weight:
5.6 lbs (2.5 kg)
Power:
115/230 VAC; 50 to 60 Hz autoranging, 14 W maximum
Operating Environment: 0
° to +50°C, Up to 90% humidity (Non-condensing)
Regulatory Compliance
• ETL, cETL (UL 60950 CAN/CSA C22.2 No. 60950, EN/IEC 60950)
• FCC Part 15A/IC-003/VCCI Class A
• C-Tick (AS/NZS 3548)
• EN 55022 Class A
• EN 61000-3-2
• EN 61000-3-3
• EN 55024
• CE Mark