beautypg.com

5 power up the chassis – CANOGA PERKINS 1200 Chassis Interconnect Module User Manual

Page 10

background image

EdgeAccess Universal Chassis System

Model 1200 CIM User Manual

2-4

2.5

Power Up the Chassis

Switch on the power supply(s) for the chassis. The CIM receives power through the backplane.
During the power-on self-test, all LEDs light amber.

At the end of self-test, check for these LED conditions:

• CLK lights Green if this CIM provides the clock; otherwise, CLK is Off
• STA lights Amber (indicates a power cycle and must be reset)
• MAJ and MIN are off

Press ALM ACK to change STA to Green.

If an alarm condition occurs in this chassis or another linked chassis:

• For a minor alarm, MIN lights Amber and the Minor alarm contacts are latched
• For a major alarm, MAJ lights Red and the Major alarm contacts are latched

Note: The MAJ or MIN LEDs turn off only when the cause of the alarm is resolved and reset.

Pressing the ALM ACK switch resets only the alarm relays, which can turn off external
device(s).