Installation locations – Kidde KN-COPP-3 (900-0076) User Manual

Page 11

background image

3. Installation Locations

• When wall mounting, place out of reach of children. Under no cir-

cumstances should children be allowed to handle the CO alarm.

• Placing the alarm at eye level allows for optimum monitoring of the

digital display.

Locations To Avoid

IMPORTANT: Improper location can affect the sensitive electronic com-
ponents in this alarm. To avoid causing damage to the unit, to provide
optimum performance, and to prevent unnecessary nuisance alarms:

• Do not install in kitchens, garages or furnace rooms that may expose

the sensor to substances that could damage or contaminate it.

• Do not install in areas where the temperature is colder than 40°F

(4.4°C) or hotter than 100°F (37.8°C) such as crawl spaces, attics,
porches and garages.

• Do not install within 5 ft. of heating or cooking appliances. (Kidde

recommends 15 ft. to prevent nuisance alarms).

• Do not install near vents, flues, chimneys or any forced/unforced air

ventilation openings.

• Do not install near ceiling fans, doors, windows or areas directly

exposed to the weather.

• Do not install in dead air spaces, such as peaks of vaulted ceilings or

gabled roofs, where CO may not reach the sensor in time to provide
early warning.

• Do not install on a switched or dimmer-controlled outlet.

• Do not install this unit near deep-cell large batteries. Large batteries

have emissions that can cause the alarm to perform at less than opti-
mum performance.

• Do not obstruct the vents located on the alarm. Do not place the

alarm where drapes, furniture or other objects block the flow of air to
the vents.