• In insect-infested areas.

• Smoke alarms should not be installed within 3 ft (.9m) of the fol-

lowing: the door to a kitchen, the door to a bathroom containing
a tub or shower, forced air supply ducts used for heating or cool-
ing, ceiling or whole house ventilating fans, or other high air flow
areas.

• Kitchens. Normal cooking may cause nuisance alarms. If a

kitchen alarm is desired, it should have an alarm silence feature
or be a photoelectric type.

• Near fluorescent lights. Electronic “noise” may cause nuisance

alarms.

• Smoke alarms are not to be used with detector guards unless

the combination (alarm and guard) has been evaluated and
found suitable for that purpose.

3. INSTALLATION INSTRUCTIONS

CAUTION: THIS UNIT IS SEALED (INCLUDING THE BATTERY).
THE COVER IS NOT REMOVABLE!

1. To insure aesthetic alignment of the alarm with the hallway or

wall, the “A” line on the
mounting bracket should be
parallel with the hallway when
ceiling mounting or horizontal
when wall mounting.

A

A

FIGURE 4

When mounting
in a hallway, the
“A” line should
be parallel with
the hallway.

A

A

Alignment Marks

(”A” Line) on

Mounting

Bracket

FIGURE 5

When wall
mounting, the
“A” line should
be horizontal.

A

A

FIGURE 6

Remove

Install