Pro-Link Wipes - Hand Sanitizers WS001 User Manual
Material safety data sheet, Hand sanitizer wipes
MATERIAL SAFETY DATA SHEET
Pro-Link, Inc.
Canton, MA 02021
GENERAL INFORMATION NUMBER: 800-74-LINKS
MEDICAL EMERGENCY NUMBER: 866-303-6948
REVISION DATE: April 26, 2007
PREPARED BY: Regulatory Compliance
DATE OF ISSUE: June 17, 2010
I - Product Identification
Hand Sanitizer Wipes
PRODUCT CODE: WS001
CHEMICAL FORMULATION: Premoistened towelette.
NFPA HAZARD IDENTIFICATION SYSTEM: HEALTH: 0
FLAMMABILITY: 3
REACTIVITY: 0
HAZARD RATING:
4 - Extreme;
3 - High;
2 - Moderate;
1 - Slight;
0 - Insignificant
II - Hazardous Ingredients
Values reported as TWA unless noted.
EPA 40 CFR:
SUBSTANCE
APPROX
%
OSHA
PEL
ACGIH
TLV
302 355 372
CAS #
Ethanol
65.0-75.0
1000 ppm
1000 ppm
N
N
N
64-17-5
Linear Alcohol Ethoxylate
< 2.00
N/E
N/E
N
N
N
34398-01-1
Key:
PEL: Permissible Exposure Limit TLV:
Threshold Limit Value C: Ceiling level STEL: Short Term Exposure Limit
N/A: Not Applicable
N/D: Not Determined
N/E: Not Established
Y: Yes
N: No
302: CERCLA List of Hazardous Substances and Reportable Quantities (40 CFR 302.4).
355: SARA TITLE III / List of Extremely Hazardous Substances for Emergency Planning and Notification (40 CFR 355).
372: SARA TITLE III / List of Toxic Chemicals subject to Release Reporting (Community Right to Know) (40 CFR 372).
III - Physical Data
BOILING POINT (
°F): N/D
SPECIFIC GRAVITY (WATER = 1): 0..876*
VAPOR PRESSURE (mm Hg): N/D
VOC CONTENT (% by weight): N/D
VAPOR DENSITY (AIR = 1): N/D
EVAPORATION RATE (WATER = 1): > 1.0*
SOLUBILITY IN WATER: Soluble*
pH: N/A
APPEARANCE AND ODOR: White cloth impregnated with a clear, colorless liquid; mint fragrance.
*Tested using the liquid component of the towelette.
IV - Fire and Explosion Hazard Data
FLASH POINT (
°F): 70*
(TEST METHOD): Closed cup
FLAMMABLE LIMITS IN AIR (VOLUME %)
UPPER: N/E
LOWER: N/E
EXTINGUISHING MEDIA: Water, foam, carbon dioxide, dry chemical.
SPECIAL FIRE FIGHTING PROCEDURES: Cool fire exposed containers with water fog. Firefighters should be equipped with full
protective gear including self-contained breathing apparatus.
UNUSUAL FIRE AND EXPLOSION HAZARD: Solvent vapors may cause flashback.