beautypg.com

Pro-Link Grout System - Enhancer D10854 User Manual

Page 3

background image

None normally required unless misting occurs, then use a NIOSH approved respirator.

Respiratory Protection:

Rubber Gloves

Skin Protection:

Safety Glasses or Goggles

Eye Protection:

Impervious clothing to avoid direct skin contact.

Other:

Local exhaust to keep below any listed TLV.

Ventilation Requirements:

Liquid

Physical Form:

Clear amber

Color:

Acid

Odor:

Over 212°F

Boiling Point:

About the same as water.

Evaporation Rate:

< 1.0

pH:

1.860

Specific Gravity:

100%

Solubility:

NE

Freezing Point:

83% (Theoretical)

% Volatile:

This product is stable at ambient temperature and pressure.

Stability:

Phosphoric oxide fumes under fire condition. Contact with common metals produces Hydrogen gas.

Hazardous Decomposition Products:

None

Hazardous Polymerization:

Bases, common metals -mild steel, copper, brass, bronze.

Incompatibility:

Page: 3 of 4

11/28/06

Grout Sytem -

Section 8 - Exposure Controls Personal Protection

Section 9 - Physical / Chemical Properties

Section 10 - Stability and Reactivity

NE

Vapor Pressure:

0

V.O.C.