Material safety data sheet, Polbio enzytab san, Pollet s.a – Pro-Link Genesan EnzyTab GEN820 User Manual
Page 2

Page : 2
MATERIAL SAFETY DATA SHEET
Revised edition no : 1
Date : 21 / 3 / 2013
Supersedes : 14 / 5 / 2012
POLBIO ENZYTAB SAN
2104466
SECTION 3 Composition/information on ingredients (continued)
Substance name
Contents
CAS No
EC No
Index No
REACH
Classification
Silicon Dioxide
:
> 1 <= 5 %
7631-86-9
-----
-----
----
Not classified. (DSD/DPD)
----------------------------------
Undefined. (GHS)
Alcohols, C9-11, ethoxylated
:
> 1 <= 5 %
68439-46-3
-----
-----
----
Xn; R22
Xi; R41
----------------------------------
Eye Dam. 1;H318
Acute Tox. 4 (Oral);H302
menthol
:
> 1 <= 5 %
89-78-1
201-939-0
-----
----
Xi; R38
----------------------------------
Undefined. (GHS)
Bronopol (INN) : 2-bromo-2-
:
> 0.1 <= 1 %
52-51-7
200-143-0
603-085-00-8
----
Xn; R21/22
Xi; R37/38-41
nitropropane-1,3 diol
N; R50
----------------------------------
Eye Dam. 1;H318
Acute Tox. 4 (Dermal);H312
Acute Tox. 4 (Oral);H302
Skin Irrit. 2;H315
STOT SE3; H335
Aquatic Acute 1;H400
(M fact. = 10)
l-Carvone
:
> 0.1 <= 1 %
6485-40-1
229-352-5
-----
----
Xn; R22
R43
----------------------------------
Acute Tox. 4 (Oral);H302
Skin Sens. 1;H317
(R)-p-mentha-1,8-diene
:
> 0.1 <= 1 %
5989-27-5
227-813-5
601-029-00-7
01-2119529223-47
R10
Xi; R38
R43
N; R50-53
----------------------------------
Flam. Liq. 3;H226
Skin Irrit. 2;H315
Skin Sens. 1;H317
Aquatic Acute 1;H400
Aquatic Chronic 1;H410
alpha-Pinene
:
> 0.1 <= 1 %
80-56-8
201-291-9
-----
----
R10
Xn; R65
R43
N; R50-53
----------------------------------
Asp. Tox. 1;H304
Flam. Liq. 3;H226
Skin Sens. 1;H317
Aquatic Acute 1;H400
Aquatic Chronic 1;H410
Composition of detergents
: < 5% : - Non-ionic surfactants - Anionic surfactants
Preservatives - Perfumes
Based on non pathogenic bacteries
SECTION 4. First aid measures
First aid measures
- Skin contact
: Not expected to require first aid measures.
- Eye contact
: Rinse immediately with plenty of water.
- Ingestion
: Drink two glasses of water. DO NOT INDUCE VOMITING. Seek medical advice.
SECTION 5. Firefighting measures
Flammable class
: Not flammable.
Extinguishing media
- Suitable extinguishing media
: Carbon dioxide. Dry chemical. Water spray.
- Unsuitable extinguishing media
: Use of heavy stream of water may spread fire.
Surrounding fires
: Use water spray or fog for cooling exposed containers.
Protection against fire
: Wear proper protective equipment.
Special procedures
: Exercise caution when fighting any chemical fire.
Pollet S.A.
In case of emergency : Centre antipoison/antigifcentrum: +32 70 245 245
Rue de la Grande Couture, 20 B-7501 Tournai-Doornik Belgique-België
Tel : +32 69 22 21 21
Fax : +32 69 21 02 83