Pro-Link 9.5% Bowl Cleaner R9505 User Manual
Page 2

2
Eye Protection Chemical Splash goggle in compliance with OSHA
regulations are advised: however , OSHA regulations also permit other
type safety glasses. Consult your safety representative.
Skin Protection Wear rubber gloves (consult your safety equipment
supplier). To prevent repeated or prolonged skin contact, wear
impervious clothing and boots.
Respiratory Protection If workplace exposure limits of product or any
component are exceeded (see exposure guidelines), NIOSH/OSHA
approved air supplied respirator is advised in the absence of proper
environmental control. OSHA relations also permit other NIOSH/OSHA
respirators (negative pressure type) under specific conditions (see
your industrial hygienist). Engineering or administrative controls should
be implemented to reduce exposure.
Engineering Controls Provide sufficient mechanical (general and
local exhaust) ventilation to maintain exposure below level of
overexposure (from known, suspected or apparent adverse effects).
SECTION - 9 PHYSICAL AND CHEMICAL
PROPERTIES
Appearance and odor pH
Thin, green liquid with a mild odor >1
Vapor Pressure Vapor Density
Unknown Unknown
Boiling Point Solubility in Water
212 Degrees Fahrenheit Complete
Percent Volatile Specific Gravity
99% (H2O =1) 1.05 +/- 0.02
SECTION - 10 STABILITY AND REACTIVITY
Chemical Stability Conditions to Avoid
Stable Temperature Extremes
Incompatibility Hazardous Decomposition
Chlorine Bleach, Other Cleaners Will not Occur
Hazardous Polymerization
Will not Occur
SECTION - 11 TOXICOLOGICAL INFORMATION
No Data Available
SECTION - 12 ECOLOGICAL INFORMATION
No Data Available
SECTION - 13 DISPOSAL CONSIDERATION
Waste Disposal Information Dispose of in accordance with all
applicable Federal, State, and Local regulations.
RCRA Information If this material becomes a waste, it would be
considered hazardous under 40 CFR 261.22. and would be classified
as EPA Waste Number D002.
SECTION - 14 TRANSPORT INFORMATION
DOT Information 49 CFR 172.101
DOT Description:
33440 Class 55
DOT Hazard Class:
8, NA 1789, II
Hazardous Component:
Hydrochloric Acid
Reportable Quantity (RQ) - 49 CFR 172.101
Not Applicable
SECTION - 15 REGULATORY INFORMATION
US Federal Regulations TSCA (Toxic Substances Control Act) Status
TSCA (United States) The intentional ingredients of this product are
listed.
CERCLA RQ - 40 CFR 355 Appendix A
5000 lbs.
SARA 302 Components 40 CFR Appendix A
None
Section 311/312 Hazard Class 40 CFR 370.2
Immediate (X) Delayed (X) Fire ( ) Reactivity ( ) Sudden Release of
Pressure ( )
SARA 313 Components - 40 CFR 372.65
CAS NUMBERS Chemical Names %
None
State and Local Regulations
California Proposition 65
None
California SCAQMD Rule 443.1 VOC’s
> 0
North Carolina Administrative Code 2D.1104 and 2B.0610
None
South Carolina Regulation 62.5 Standard Number 8
None
SECTION - 16 OTHER INFORMATION
The information accumulated herein is believed to be accurate but is
not warranted to be whether originating with the company or not.
Recipients are advised to confirm in advance of need that the
information is current, applicable and suitable to their circumstances.
This information was compiled from current manufacturer’s MSDS’s of
the component parts of the product as well as other sources, such as:
Code of Federal Regulations 29, Revised as of July 1. 1994.
Code of Federal Regulations 40, Revised as of July 1, 1994.
ACGIH, Guide to Occupational Exposure Values, 1996.