MATERIAL SAFETY DATA SHEET
___________________________________________________________________________________
Date of last change 22/03/10
Page 2 of 4
Auto Ignition Temperature (ºC)
204-465
Special Procedures
Water from fogging nozzles may be used to cool closed
containers to prevent build up if exposed to extreme
temperatures. Full protective equipment including self
contained breathing apparatus should be worn in a fire
involving this material.
Flammability Flammable
If yes, under which conditions?
Excessive heat, sparks and open flame
Extinguishing media
Water, Carbon Dioxide, Dry Chemical, Foam
Upper Flammable limit (% by volume)
23.5
Lower Flammable limit (% by volume)
1.2
Explosion Data – Sensitivity to static
discharge
Not Applicable
Explosion Data – Sensitivity to impact
Not Applicable
Hazardous combustion – Products
Hygdrocarbon fumes and smoke. Carbon Monoxide where
combustion is incomplete.
Aerosol flame projection – classified as:
15 – 45 cm
Aerosol flame projection – flashback:
None
Flash Point (ºC), Tag Closed-Cup
(Concentrate)
Lowest known value is acetone @ -18ºC
Leak/spill
Remove all sources of ignition. Use an inert absorbent material, and
non-sparking tools. Ventilate area. Prevent from entering a
watercourse.
Storage Needs
Keep away from heat, sparks, and open flames
Engineering controls
Ventilation – Local (Mechanical if used indoors on a continuous basis)
Handling Procedures and
Equipment
Store in a cool, well ventilated area not to exceed 50 deg. C
Synergistic Materials
None known
Gloves / Type
Not normally required
Respiratory / Type
Not normally required
Eye / Type
Safety Glasses
Footwear / Type
Not normally required
Other / Type
Not required
5. FIRE
FIGHTING
METHODS
6. ACCIDENTAL
RELEASE
MEASURES
7. HANDLING
&
STORAGE
8.
EXPOSURE CONTROLS / PERSONAL PROTECTION