Fire fighting measures, Accidental release measures, Handling and storage – Pro-Link Air Freshener & Deodorizer - Crisp Linen YA013 EN User Manual
Page 2: Exposure controls / personal protection, Physical & chemical properties
Flammable properties
Vapor or gas may spread to distant ignition sources and flash back. Runoff to sewer may
cause fire or explosion hazard.
.
5. Fire Fighting Measures
space
Suitable extinguishing media
Water fog. Dry chemical. Carbon dioxide (CO2).
Extinguishing media
space
Protective equipment and
precautions for firefighters
In case of fire and/or explosion do not breathe fumes. Containers should be cooled with
water to prevent vapor pressure build up.
Protection of firefighters
space
Methods for containment
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the
leak is irreparable. Stop the flow of material, if this is without risk.
.
6. Accidental Release Measures
space
Methods for cleaning up
Should not be released into the environment. Use a non-combustible material like
vermiculite, sand or earth to soak up the product and place into a container for later
disposal.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface
thoroughly to remove residual contamination.
space
Handling
Pressurized container: Do not pierce or burn, even after use. Do not smoke while using
or until sprayed surface is thoroughly dry. Do not use if spray button is missing or
defective. Do not re-use empty containers. Avoid prolonged exposure.
.
7. Handling and Storage
space
Storage
Contents under pressure. Do not puncture, incinerate or crush. The pressure in sealed
containers can increase under the influence of heat. Keep away from heat and flame. Do
not expose to heat or store at temperatures above 120°F/49°C as can may burst. Avoid
exposure to long periods of sunlight. Keep out of the reach of children. Keep away from
food, drink and animal feedingstuffs. Level 1 Aerosol (NFPA 30B)
space
Exposure limits
ACGIH
Components
CAS #
Propane
74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
n-Butane
106-97-8
1000 ppm
Not established
Not established
.
8. Exposure Controls / Personal Protection
space
OSHA
Components
space
CAS #
Propane
74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
Eye / face protection
Chemical goggles are recommended.
Personal protective equipment
space
Skin protection
Wear appropriate chemical resistant clothing. Chemical resistant gloves.
space
Respiratory protection
When workers are facing concentrations above the exposure limit they must use
appropriate certified respirators. If permissible levels are exceeded use NIOSH
mechanical filter / organic vapor cartridge or an air-supplied respirator.
space
Appearance
Compressed liquefied gas.
.
9. Physical & Chemical Properties
space
Boiling point
190.4 °F (87.8 °C) estimated
space
Color
White.
space
Density
0.8541 g/cm3 estimated
space
Flammability (HOC)
12.9138 kJ/g estimated
space
Flash back
No
space
Flash point
-156 °F (-104.4 °C) Propellant
space
Form
Aerosol.
space
Product name: Ord-Aire Air Freshener
Product #: 575-004 Revision date: 28-FEB-2011 Print date: 28-FEB-2011
MSDS US
2 / 5
Crisp Linen Air Freshener & Deodorizer