Fire fighting measures, Accidental release measures, Handling and storage – Pro-Link STAINLESS STEEL POLISH & CLEANER KA006 EN User Manual
Page 2: Exposure controls / personal protection, Physical & chemical properties

Flammable properties
Vapor or gas may spread to distant ignition sources and flash back. Runoff to sewer may
cause fire or explosion hazard.
.
5. Fire Fighting Measures
space
Suitable extinguishing media
Foam. Dry chemical. Carbon dioxide (CO2). Do not use water jet.
Extinguishing media
space
Protective equipment and
precautions for firefighters
In case of fire and/or explosion do not breathe fumes. Containers should be cooled with
water to prevent vapor pressure build up. Move containers from fire area if you can do so
without risk.
Protection of firefighters
space
Methods for containment
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the
leak is irreparable. Stop the flow of material, if this is without risk.
.
6. Accidental Release Measures
space
Methods for cleaning up
Should not be released into the environment. Use a non-combustible material like
vermiculite, sand or earth to soak up the product and place into a container for later
disposal.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface
thoroughly to remove residual contamination.
space
Handling
Pressurized container: Do not pierce or burn, even after use. Do not smoke while using
or until sprayed surface is thoroughly dry. Use only in area provided with appropriate
exhaust ventilation. Do not use if spray button is missing or defective. Do not re-use
empty containers. Avoid prolonged exposure.
.
7. Handling and Storage
space
Storage
Contents under pressure. Do not puncture, incinerate or crush. Do not handle or store
near an open flame, heat or other sources of ignition. Avoid exposure to long periods of
sunlight. Store in cool place. Keep out of the reach of children. Keep away from food,
drink and animal feedingstuffs. Level 1 Aerosol (NFPA 30B)
space
Exposure limits
ACGIH
Components
CAS #
n-Butane
106-97-8
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
Propane
74-98-6
1000 ppm
Not established
Not established
.
8. Exposure Controls / Personal Protection
space
OSHA
Components
space
CAS #
Propane
74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
Eye / face protection
Not normally needed.
Personal protective equipment
space
Skin protection
Chemical resistant gloves.
space
Respiratory protection
If permissible levels are exceeded use NIOSH mechanical filter / organic vapor cartridge
or an air-supplied respirator.
space
Appearance
Compressed liquefied gas.
.
9. Physical & Chemical Properties
space
Boiling point
266 °F (130 °C) estimated
space
Color
White.
space
Density
0.8303 g/cm3 estimated
space
Flammability (HOC)
17.9319 kJ/g estimated
space
Flash back
No
space
Flash point
-156 °F (-104.4 °C) Propellant
space
Form
Aerosol.
space
Product name: Water Base Stainless Steel Maintainer
Product #: 844-006 Revision date: 11-JAN-2013 Print date: 11-JAN-2013
MSDS US
2 / 5
PRO-LINK STAINLESS STEEL POLISH & CLEANER