Accidental release measures, Handling and storage, Exposure controls / personal protection – Pro-Link Citrus Cleaner YA010 EN User Manual
Page 2: Physical & chemical properties

Suitable extinguishing media
Large Fires: Water spray, fog or regular foam.
Small Fires: Dry chemical, CO2, water spray or regular foam.
Extinguishing media
space
Protective equipment and
precautions for firefighters
In the event of fire and/or explosion do not breathe fumes. Wear full protective clothing,
including helmet, self-contained positive pressure or pressure demand breathing
apparatus, protective clothing and face mask. Containers should be cooled with water to
prevent vapor pressure build up. For massive fire, use unmanned hose holders or
monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Protection of firefighters
space
Methods for containment
Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area).
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the
leak is irreparable.
.
6. Accidental Release Measures
space
Methods for cleaning up
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean contaminated
surface thoroughly.
space
Handling
Pressurized container: Do not pierce or burn, even after use. Do not handle or store near
an open flame, heat or other sources of ignition. Use only in area provided with
appropriate exhaust ventilation. Do not use if spray button is missing or defective. Do not
get this material in contact with eyes. Do not get this material in contact with skin. Avoid
prolonged exposure.
.
7. Handling and Storage
space
Storage
Level 1 Aerosol.
Contents under pressure. Do not puncture, incinerate or crush. The pressure in sealed
containers can increase under the influence of heat. Keep away from heat, sparks, and
flame. Avoid exposure to long periods of sunlight. Store in cool place. Keep the container
dry. Keep out of the reach of children.
space
Exposure limits
ACGIH
Components
CAS #
Propane
74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
n-Butane
106-97-8
1000 ppm
Not established
Not established
.
8. Exposure Controls / Personal Protection
space
OSHA
Components
space
CAS #
Propane
74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
Eye / face protection
Not normally needed.
Personal protective equipment
space
Skin protection
Protective gloves. Not normally needed.
space
Respiratory protection
No personal respiratory protective equipment normally required.
space
Appearance
Compressed liquefied gas.
.
9. Physical & Chemical Properties
space
Boiling point
204.8 °F (96.1 °C) estimated
space
Color
White.
space
Flammability (HOC)
4.6876 kJ/g estimated
space
Flash back
No
space
Flash point
-156 °F (-104.4 °C) estimated
space
Form
Aerosol.
space
Odor
fruity
space
pH
9 - 10
space
Physical state
Liquid.
space
trade_name
Product #: 985-001 Revision date: 24-MAR-2009 Print date: 24-MAR-2009
MSDS US
2 / 4