Error message, Rough-in drawing warmers – Wilbur Curtis GEMTS User Manual
Page 5

5
Model Select
Error Message
An error message will appear on the screen in
the event of a malfunction under the following
conditions:
1. Water Level Overflow.
2. Break in Temperature Control Circuit
3. Excess Temperature in Heating Tank
To turn off an error message, press the button
for five seconds.
Model Select (Factory set to Gemini-Twin IF)
Press to select, < or > to select model. The selections are: ThermoPro‑Twin, ThermoPro‑Single, Gemini‑Twin, Gemini‑
Single, Milano‑Twin, Milano‑Single, Gemini‑Twin IF, Gemini‑Single IF, Tpro‑1Gal‑Twin and Tpro‑1Gal‑Sngl. Press to set.
When the Model Select feature is changed, all settings are reset to the defaults of the newly selected model.
Language (Factory set to English)
Press to select, < or > to select language. The selections are: English or French. Press to set. When the Language
feature is changed, all screens will read the selected language.
Language
Rough-In Drawing
Warmers
The warmer, under the brewcone will turn on automatically whenever
a coffee brew cycle is started. The warmers can be switched on or off
at the two WARMER buttons on on the control panel.
LEFT & RIGHT
SATELLITE WARMERS
29.63”
(75.3 cm)
4.00”
(10.1 cm)
6.75”
(17.1 cm)
5.38”
(13.7 cm)
11.00”
(27.9 cm)
11.13”
(28.3 cm)
1.00”
(2.54 cm)
18.13”
(46.0 cm)
22.13”
(56.2 cm)