Pulse brew, Brew cycle counter – Wilbur Curtis TLP User Manual
Page 3

3
ON
OFF
ENTER THE PROGRAMMING MODE #2:
will now start a pattern of LONG and SHORT blinks.
This pattern identifies the number of brew cycles. SHORT blinks indicate
the brew number from one [1] to nine [9]. LONG blinks separate the 1’s,
10’s, 1,000’s and 10,000’s.
ENTER THE PROGRAMMING MODE #1
(Be sure to have an empty brewcone & airpot in position).
Press and HOLD until hot water starts running from sprayhead;
then RELEASE.
When desired volume is reached, press
again to stop flow and set
brew volume.
CHANGE FULL BREW VOLUME
When setting the brew volume, place an empty airpot under the brewcone to determine volume level. The factory default for the Half Brew but-
ton is half the brew volume of the Full Brew button. The brew volume of the Half Brew button can be set independently (see Half Brew Volume
below).
Before changing the brew volume, wait until unit
reaches brew temperature (Ready to Brew light comes
on), insert the brewcone into place on the brewer, then
place an airpot or some kind of measuring container
centered beneath the brewcone.
Brew Volume - Factory Pre-set Full Brew to 2.2 Liters
BREW CYCLE COUNTER
TO ACCESS BREW CYCLE COUNTER
Turn OFF the power from the Control Panel by press-
ing .
Press and HOLD and press and RELEASE
Continue HOLDING until
STOPS blink-
ing; RELEASE.
ENTER THE PROGRAM MODE #2
ENTER THE PROGRAMMING MODE #1
Have an empty brewcone & airpot in position under the sprayhead.
Press and HOLD until hot water starts running from sprayhead;
then RELEASE.
When desired volume is reached, press
again to stop flow and set
brew volume.
HALF BREW VOLUME
Turn OFF the power from the Control Panel by press-
ing .
Press and HOLD and press and RELEASE
.
Continue HOLDING until
STOPS blinking
and remains on, then RELEASE
.
will now blink one of three different flashing light
patterns (refer to Pulse Options, right).
PULSE BREW
CHANGING THE PULSE BREW FEATURE
ENTER THE PROGRAM MODE #3
To change:
PULSE OPTIONS:
OFF = One Long Flash (Factory Default)
#1 = One Long Flash + 1 Short Flash
#2 = One Long Flash + 2 Short Flash
#3 = One Long Flash + 3 Short Flash
Option #1 produces a pulse of 40 seconds ON, 40 seconds OFF, then
ON until the end of the brew cycle.
Option #2 provides a pulse of 30 seconds ON, 5 seconds OFF, repeated
four times, then continuously ON until the end of the brew cycle.
Option #3 is 40 seconds ON, 40 seconds OFF, 60 seconds ON, 25
seconds OFF, then ON until the end of the brew cycle.
Press and HOLD until shows one quick flash, then
RELEASE. You have now added a blink to your blinking light pattern.
By pressing and holding you add another blink.
To set and exit, press .