1 main operation interface functions – Zigen HX-44 User Manual
Page 16
Matrix Switching System—User Manual
15
6.0.2.1 Main Operation Interface Functions
Refer to the main configuration screen as above, the marked blue area shows crossing
matrix of output ports 01-04 and input ports 01-04. Basic operation is described as
below:
Example, Selecting Matrix Switching Functions:
HX-44 matrix having all the input/output ports properly connected to the equipment. If
you want to set channel 1 input to channel 2, 3 and 4 output; channel 3 input to channel
1 output. There are 2 ways to implement the switching. Please follow the ways and steps
to finish the switching functions:
First: Make sure you have selected
“Video” check box (
). Directly click on the
corresponding icons on the matrix
to transform them into
to complete the
switching operation.
Second:
Step 1: Make sure you have selected
“Video” check box (
).
Step 2: Select the
“Output” number keys 02, 03 and 04 to the right of the blue
configuration area, and select the
“Input” number key 01 below. Then,
press consecutively the previously selected
“Output” number keys 02, 03
and 04 (or you can press the
“Deselect all output” key). This way, you have
selected
“Input” 01 and “Output” 02, 03 and 04 switching.
Step 3: First select the
“Output” number key 01 to the right of the blue configuration
area, and select the
“Input” number key 03 on the bottom. Then, press the
previously selected
“Output” number key 01 (or you can press the
“Deselect all output” key). This way, you have selected Input 03 and
Output 01 switching.
Upon completion of the above 3 steps, you have actually completed the switching
operation of having channel 1 input to channel 2, 3 and 4 output while at the same time
successfully switched from channel 3 input to channel 1 output.
The main configuration screen also shows you some function buttons for easy operation:
Disconnect: To disable the connections. After you had configured the connection
between input and output ports, you can click this button to disable the connections.
Select all output: Click this button to select all output ports including output 01~04.
Deselect all output: Click this button to cancel presently selected output ports. After you
had configured a connected combination, please click this button first for next settings.
Disconnect all: To stop feed to all connections.