Short Loop Test

The Short Loop Test is a simple test to determine if each component (Fence
Transmitter, Receiver Collar and Boundary Wire) is functioning properly.

Disconnect the Boundary Wire.

1.

Cut approximately 10 feet of unused Boundary Wire and connect it to the

2.

Boundary Wire Terminals.
Spread the Boundary Wire out into a circle. Set the Boundary Control Switch to B.

3.

Set the Boundary Width Control knob to 10.

4.

If the Loop Indicator Light is not lit, then your Fence Transmitter is not

5.

functioning properly. Contact the Customer Care Center at 1-800-732-2677.
If the Loop Indicator Light is lit, disconnect one end of the Boundary Wire from

6.

the Boundary Wire Terminal.
If the loop alarm does not sound, the Fence Transmitter needs to be replaced.

7.

Contact the Customer Care Center at 1-800-732-2677.
If the loop alarm does sound, plug the Boundary Wire back into the Boundary

8.

Wire Terminal.
Hold the Test Light Contacts to the Receiver Contact Points. Hold the Receiver

9.

Collar next to the 10-foot length of Boundary Wire. The Receiver Collar should
beep about one foot away from the Boundary Wire. The Test Light should then
fl ash as you hold the Receiver Collar closer to the Boundary Wire.