Symptom

Probable Cause

Solution

Failure to engage

Air not getting to the B-275 due
to a control valve malfunction

Check for a control vlave malfunction or low air
pressure nad replace the control valve if
necessary.

Air leaks around the O-ring Seals

Replace the O-ring Seals.

Lack of lubrication on the Hub

spline or in the Air Chamber

Lubricate the Hub spline with a thin film of Never

Seez® or check the air line lubricator settings.

Failure to disengage

Unexhausted air due to control

valve malfunction

Check for a control valve malfunction and
replace the control valve if necessary.

Lack of lubrication on the hub

spline or in the Air Chamber

Lubricate the Hub spline with a thin film of Never

Seez® or check the air line lubricator settings.

Broken Wave Spring

Replace Wave Spring.

Loss of torque

Air leaks around the O-ring Seals

Replace the O-ring Seals.

Worn or contaminated Friction

Facings

Replace the Friction Disc.

Excessive drag on the air line

Defective Ball Bearings

Replace Ball Bearings.

Air line not properly supported

Position the air line against a support that is
parallel to the centerline of the B-275.