Electrical Installation
Wire DIN Connector to the appropriate power supply
or PLC output. See Tables below for specifications.
CAUTION
24 VDC valve connector has a
suppression diode installed across the
coil. Observe proper voltage polarity or
connector damage will result.
Brown
White
DIN Connector
Solenoid Valve
Customer Supplied
Power Supply
SOLENOID
COIL
DIODE
24 VDC
Figure 3 Example Solenoid Circuit
Exhaust Valve
Solenoid
DIN Connector
Figure 4
Notice:
The previous valve kit (Part Number 964650)
shown to the right is now obsolete. If replacing
the obsolete valve, ensure that the new
installation directions are followed. The new
DIN connector supplied with the kit should be
used or else the functionality of the suppression
diode and the LED indicator will be lost.
Electrical Specifications
Voltage
24 VDC
Voltage Tolerance
+10%, -15%
Power
4 Watts
Coil Temperature Rise
32°C (90°F)
Din Connector
Cable Wire Color
Valve
24 VDC
Valve Pin
Brown
+
1
White
-
2
Green
Ground
Ground