beautypg.com

Electrical installation – Nexen 3-Way Valve 964650 User Manual

Page 2

background image

2

Solenoid Kit Installation Guide

ISO 9001 Certified

Nexen has sales offices throughout the United States,
Europe, Japan, and Australia.

www.nexengroup.com

In accordance with Nexen’s established policy of constant product
improvement, the specifications contained in this document are subject
to change without notice. Technical data listed in this document are
based on the latest information available at the time of printing and are
also subject to change without notice. For current information, please
consult www.nexengroup.com.

Nexen Group, Inc.
560 Oak Grove Parkway
Vadnais Heights, MN 55127

800.843.7445
Fax: 651.286.1099
www.nexengroup.com

©2013 Nexen Group, Inc.

FORM NO: L-21281-A-0813

Electrical Installation

Wire DIN Connector to the appropriate power supply
or PLC output. See Tables below for specifications.

CAUTION

24 VDC valve connector has a
suppression diode installed across the
coil. Observe proper voltage polarity or
connector damage will result.

Brown

White

DIN Connector

Solenoid Valve

Customer Supplied

Power Supply

SOLENOID

COIL

DIODE

24 VDC

Figure 3 Example Solenoid Circuit

Exhaust Valve

Solenoid

DIN Connector

Figure 4

Notice:

The previous valve kit (Part Number 964650)
shown to the right is now obsolete. If replacing
the obsolete valve, ensure that the new
installation directions are followed. The new
DIN connector supplied with the kit should be
used or else the functionality of the suppression
diode and the LED indicator will be lost.

Electrical Specifications

Voltage

24 VDC

Voltage Tolerance

+10%, -15%

Power

4 Watts

Coil Temperature Rise

32°C (90°F)

Din Connector

Cable Wire Color

Valve

24 VDC

Valve Pin

Brown

+

1

White

-

2

Green

Ground

Ground

This manual is related to the following products: