Campbell Hausfeld SDM-CAN User Manual
Page 54
SDM-CAN CAN-Bus Interface User Guide
29
Read SDM-CAN status
Status Description
0000
The SDM-CAN has bus activities; error counters < 96.
0001
The SDM-CAN has bus activities; at least one error
counter is >= 96.
0002
The SDM-CAN is not involved in bus activities; error
counters < 96.
0003
The SDM-CAN is not involved in bus activities; at least
one error counter >=96.
30
Read SDM-CAN operating system and version number
31
Send Remote Frame Request.
32
Set SDM-CAN's internal switches
Switch Code Description
A
0
Not
used
B
0
returns the last value captured (default)
1 returns –99999 if value already read by
datalogger
C
0
Disable interrupts (default)
1 Enable
pulse
interrupts
2
Enable fast interrups
3-7
Not
defined
8
Place the SDM-CAN into low power
stand-by mode.
9
Leave switch setting unchanged.
D
0
Listen only (error passive) mode.
1
Transmit once.
2 Self-reception.
3 Normal
retransmission
4 Transmit
once
5
Self-reception; self -test.
6
Normal; self-test.
7
Active at power-up.
8 Not
defined.
9
Leave switch setting unchanged.
33
Read SDM-CAN's internal switches (see above)
B-2