beautypg.com

Ii - specifications – Bradford White IGI-180R-10N User Manual

Page 9

background image

9

II - SPECIFICATIONS

- GENERAL

Model type

RESIDENTIAL

COMMERCIAL

Type of appliance

Temperature controlled continuous
flow gas hot water system

Operation

With / without remote controls, mounted
in kitchen, bathroom, etc.

Exhaust system

Direct Vent - Forced combustion

Maximum/Minimum gas rate

180,000 BTU's - 15,000 BTU's Natural Gas

(Input BTU's)

180,000 BTU's - 15,000 BTU's Propane Gas

Hot water capacity,

0.5 to 6.5 GPM

(50°F rise)

Setpoint Temperature

Factory setting - 120°F

Factory setting - 140°F

(without remote)

Temperature range

MC controller : 96 - 160°F

(with remote)

BC controller : 96 - 120°F

MCC controller : 96-180°F

BSC controller : 96 - 120°F

Approved gas type

Natural or Propane - Ensure unit matches
gas supply type.

Installation

Indoor Only

Dimensions

Height 23 5/8"
Width 13 25/32"
Depth 8 13/16"

Weight

49 Lbs.

Thermal Efficiency rating

0.87 (Propane) 0.82 (Natural)

Noise level

49 dB (A)

Connections

Gas supply 3/4" NPT (Male)
Cold water inlet 3/4" NPT (Male)
Hot water outlet 3/4" NPT (Male)

Ignition system

Direct electronic ignition

Electrical consumption

Operating - 75 watts
Standby - 5.5 watts
Anti-frost protection 100 watts

Water temperature control

Simulation feedforward and feedback.

Water flow control

Water flow sensor, electronic water control
device, and electronic by-pass control device

Recommended Minimum water
supply pressure

20 PSI (recommend 50-80 PSI for maximum performance)

Maximum water supply pressure

150 PSI