beautypg.com

Notice – Bradford White TG-199E-N User Manual

Page 43

background image

43

2. To set the desired temperature on the control, all hot water faucets must be closed. If there

are remote controls installed, press the “Priority” button on the control you want to change the
setting on and the “Priority” indicator light will glow.

3. Press the “H” or “C” button until the required temperature is displayed on the digital monitor.

The default available water temperature range for the main control is 98-120ºF.

4. To operate the water heater, simply turn any hot water tap on. This will automatically light the

burner and provide hot water at the preset temperature. If the optional remote controls have
been installed, the “IN USE” indicator light will glow on all remote controls.

5. The control(s) can also display diagnostic codes, water flow rate through the unit (in gallons

per minute) and the outlet water temperature.

6. Press and hold the “Priority” button for 2 seconds and without releasing, press the “H” button

to display a sequence of up to 9 diagnostic codes, if any, stored in memory that has been
experienced. Any diagnostic codes will be displayed on the digital monitor in sequence
starting with the most recent code.

7. Press and hold the “H” button for 2 seconds and without releasing, press the “Priority” button

to display the water flow through the water heater with hot water in use (GPM = Display
Readout X 0.1).

8. Press and hold the “C” button for 2 seconds and without releasing, press the “Priority” button

to display the outlet water temperature while in use (degrees F).

°F

Set Temperature

In Use

Priority

e n d l e s s h o t w a t e r s y s t e m

CAUTION: Hotter water increases the risk
of scald injury. Before changing temperature
setting, see instruction manual.

C O R P O R A T I O N

R

P

o

B

Pri rity

utton

Temperature

Display

In Use

Indicator

Priority

Button

Priority

Indicator

Thermostat

Figure 17.

Remote Control and the Description of Functions on All Controls.

NOTICE

The temperature can only be adjusted between 96

F and 110F when the hot water tap is open and

hot water is flowing. This is a safety feature to prevent scalding while hot water is in use.

NOTICE

The default temperature setting that will appear when the water heater is first connected to the
electrical supply is 104ºF. In the event of a power interruption, the unit will retain its set temperature
for up to 6 hours. If the power is interrupted for more than 6 hours, the unit will revert back to a
temperature of 104°F.