Electrical Connections

Before any electrical connections are made, be sure that the water heater is
full of water and that the manual shut-off valve in the cold water supply line is
open. Check the rating plate and wiring diagram before proceeding. This
electric water heater was built and wired in accordance with the INTERTEK
testing approvals requirements. The temperature limiting device is of the
manual reset, trip-free type and has been factory installed to interrupt all
ungrounded power supply conductors in the event of thermostat failure.
Thermostats are factory set and wired in accordance with the wiring diagram
fastened to the inside of the top access panel. The plumbing supplier in your
area ordered this heater wired at the factory to comply with existing area
codes, but local utility codes may require or allow other circuitry. Consult
your local power company to determine the correct electrical hook-up in
order to meet local utility and building codes and in order to obtain the most
economical rates. Also check to find out if you are required to obtain a
permit before starting the installation. The following chart shows the
recommended fuse size for the maximum water heater wattage. The
maximum wattage and rated voltage are shown on the water heater data
plate. The water heater must be well grounded. A green ground screw is
provided at the electrical connection point for connecting a ground wire.

RECOMMENDED FOR AMPERAGE

MAX WATTS RATED VOLTS MAX WATTS RATED VOLTS

120V 208V 240V 208V

240V

600 10A

5A

5A

3500 25A 20A

750 10A

5A

5A

3800 25A 25A

1000 15A 10A 10A

4000

25A 25A

1250 15A 10A 10A

4500

30A 25A

1500 20A 10A 10A

5000

35A 30A

2000 25A 15A 15A

5500

35A 35A

2500 30A 20A 15A

6000

40A 35A

3000 35A 20A 20A