TROUBLESHOOTING

(In addition to instruction manual.)

LED Status

Control Status

Probable Cause

None (LED not on

or flashing)

Elect rical pow er not

present

1. Cont rol pow er sw it ch in " OFF" posit ion
2. Supply volt age int errupted

One short f lash

every f our

seconds

St and-by mode,

Thermost at is sat isf ied (no

f aults)

Temperat ure demand is sat isf ied (no call f or
heat )

Alt ernat es bright

and dim

(heart beat )

Thermost at calling f or heat

(no f ault )

Tank t emperat ure below set point of
t hermost at

Short f lash once

every second

Weak pilot signal on last

call f or heat

1. Unst able pilot
2. Pilot t ube block or rest rict ed
3. Oxidat ion build-up on pilot elect rode
4. Wire damage t o pilot assembly or bad
connect ion at gas valve

Tw o f lashes,
t hree second

pause

Relay not w orking

Fault y relay

Three f lashes,

t hree second

pause

Relay not w orking

Fault y relay

Four f lashes,
t hree second

pause

Excessive t ank

temperat ure, syst em must

be reset

1. Thermal w ell sensor out of calibrat ion
2. Fault y gas valve

Five f lashes,

t hree second

pause

False pilot f lame present

Pilot valve stuck in open posit ion

Six f lashes, one

f lash, t hree

second pause

(Sof t Lockout )

Failed t o light pilot ,

syst em reset s af t er (5)

minut es

1. Unst able pilot
2. Pilot t ube block or rest rict ed
3. Oxidat ion build-up on pilot elect rode
4. Wire damage t o pilot assembly or bad
connect ion at gas valve