beautypg.com

Pdx series – Bradford White PDX-75S-70FB-3X User Manual

Page 37

background image

PDX Series

Installation of Inner Door With
Gasket.

WARNING

Stripped fastener connections may allow

for seal breach of inner door. A seal

breach may result in a fire or explosion

causing property damage, personal

injury or death. Do not over tighten

screws in steps 8, 10 and 11.

If a fastener connection is stripped,

contact the manufacturer listed on the

water heater rating plate.

Step 7.

Clean any residual gasket residue or other debris
from combustion chamber surface before installing
the inner door/gasket assembly.

Step 8.

Place the left side inner door into position first.
Firmly position the radiused channel of the inner
door around

the feedline. Using the 1/4”

hex drive

screws from step 3d, secure left side inner door in
place. DO NOT OVER TIGHTEN SCREWS.

Step 9

Position thermocouple, pilot tube and Piezo wire
against left side inner door flange gasket. DO
NOT ROUTE THROUGH RADIUSED
CHANNEL WITH FEEDLINE.

Radiused Channel for

Feedline

PDX SERVICE PROCEDURE XIII

Inner Door/Gasket Removal, Inspection

Replacement and Reinstallation

Igniter wire and pilot tube

shown in proper position.

Page 37

37

37