Venting (Part II) continued-

TABLE 6

VENT CONNECTOR LENGTHS FOR 3” (7.6 cm) DIAMETER VENT PIPE

Terminating

# of 90

Elbows

(excluding vent

terminal)

Max straight

Length

ft (m)

Min straight

Length

ft (m)

Through the Wall

1

115 (35) 10

(3.1)

Through the Wall

2

110 (33.5) 10

(3.1)

Through the Wall

3

105 (32.0) 10

(3.1)

Through the Wall

4

100 (30.5) 10

(3.1)

Through the Wall

5

95 (29.0) 10

(3.1)

Through the Roof

0

120 (36.6) 15

(4.6)

Through the Roof

1

115 (35) 15

(4.6)

Through the Roof

2

110 (33.5) 15

(4.6)

Through the Roof

3

105 (32.0) 15

(4.6)

Through the Roof

4

100 (30.5) 15

(4.6)

NOTE: When using 3” (7.6 cm) vent pipe, use a 3” (7.6 cm) to 2” (5.1 cm)
reducer and exit the building wall with 2” (5.1 cm)
vent pipe using the 2”
(5.1 cm)
45

vent terminal supplied. Two 45 elbows are equivalent to one

90

elbow. Each 90° elbow is equivalent to 5 feet (1.5 m) of straight vent

pipe.

CONNECTION TO 2” (5.1 CM)

VENT PIPE

CONNECTION TO 3” (7.6 CM)

VENT PIPE

Figure 6