Venting (Part I) continued-

sure the vent pipe terminal elbow fitting is at least 1” (2.5 cm) away from the
edge of the wall.

TABLE 1 - VENT CONNECTOR LENGTHS

FOR 3” (7.6 cm) DIAMETER VENT PIPE

Terminating

# of Elbows

Maximum straight

Length ft (m)

Minimum

straight

Length

ft (m)

48, 65 gal.

Through the Wall

1 55

(16.8)

2 (.6)

Through the Wall

2 50

(15.2)

2 (.6)

Through the Wall

3 45 (13.7)

2 (.6)

Through the Wall

4 40

(12.2)

2 (.6)

Through the Roof

0 60

(18.3)

7 (2.1)

Through the Roof

1 55

(16.8)

7 (2.1)

Through the Roof

2 50 (15.2)

7 (2.1)

Through the Roof

3 45 (13.7)

7 (2.1)

TABLE 2 -VENT CONNECTOR LENGTHS

FOR 4” (10.2 cm) DIAMETER VENT PIPE

Terminating

# of 90

Elbows (excl.

vent term.)

Maximum straight

Length ft (m)

Min

straight

Length

ft (m)

48, 65 gal.

Through the Wall

1 175

(53.3)

10 (3.1)

Through the Wall

2 170

(51.8)

10 (3.1)

Through the Wall

3 165

(50.3)

10 (3.1)

Through the Wall

4 160

(48.8)

10 (3.1)

Through the Wall

5 155

(47.2)

10 (3.1)

Through the Roof

0 180

(54.9)

15 (4.6)

Through the Roof

1 175

(53.3)

15 (4.6)

Through the Roof

2 170

(51.8)

15 (4.6)

Through the Roof

3 165

(50.3)

15 (4.6)

Through the Roof

4 160

(48.8)

15 (4.6)

NOTE: When using 4” (10.2 cm) vent pipe, use a 4” (10.1 cm) to 3” (7.6
cm)
reducer and exit the building wall with 3” (7.6 cm) vent pipe using the