Venting (Part I) continued-
sure the vent pipe terminal elbow fitting is at least 1” (2.5 cm) away from the
edge of the wall.
TABLE 1 - VENT CONNECTOR LENGTHS
FOR 3” (7.6 cm) DIAMETER VENT PIPE
Terminating
# of Elbows
Maximum straight
Length ft (m)
Minimum
straight
Length
ft (m)
48, 65 gal.
Through the Wall
1 55
(16.8)
2 (.6)
Through the Wall
2 50
(15.2)
2 (.6)
Through the Wall
3 45 (13.7)
2 (.6)
Through the Wall
4 40
(12.2)
2 (.6)
Through the Roof
0 60
(18.3)
7 (2.1)
Through the Roof
1 55
(16.8)
7 (2.1)
Through the Roof
2 50 (15.2)
7 (2.1)
Through the Roof
3 45 (13.7)
7 (2.1)
TABLE 2 -VENT CONNECTOR LENGTHS
FOR 4” (10.2 cm) DIAMETER VENT PIPE
Terminating
# of 90
Elbows (excl.
vent term.)
Maximum straight
Length ft (m)
Min
straight
Length
ft (m)
48, 65 gal.
Through the Wall
1 175
(53.3)
10 (3.1)
Through the Wall
2 170
(51.8)
10 (3.1)
Through the Wall
3 165
(50.3)
10 (3.1)
Through the Wall
4 160
(48.8)
10 (3.1)
Through the Wall
5 155
(47.2)
10 (3.1)
Through the Roof
0 180
(54.9)
15 (4.6)
Through the Roof
1 175
(53.3)
15 (4.6)
Through the Roof
2 170
(51.8)
15 (4.6)
Through the Roof
3 165
(50.3)
15 (4.6)
Through the Roof
4 160
(48.8)
15 (4.6)
NOTE: When using 4” (10.2 cm) vent pipe, use a 4” (10.1 cm) to 3” (7.6
cm) reducer and exit the building wall with 3” (7.6 cm) vent pipe using the
- TW4-65S-70FB-3N TW4-50S-67FB-3N M-2-TW-75T6SX M-2-TW-65T6FSX M-2-TW-50T6FSX M-4-TW60T6FSX M-4-TW50T6FSX M-4-TW40T6FSX M-1-TW-60T6FSX M-1-TW-50S6FSX M-1-TW-40S6FSX U-2-TW-75T6RN U-2-TW-65T6FRN U-2-TW-50T6FRN U-4-TW-60T6FRN U-4-TW-50T6FRN U-4-TW-40T6FRN U-1-TW-60T6FRN U-1-TW-50S6FRN U-1-TW-40S6FRN M-2-TW-75T6BN M-2-TW-65T6FBN M-2-TW-50T6FBN M-4-TW60T6FBN M-4-TW50T6FBN M-4-TW40T6FBN