Dell precision workstation 620 computer – Dell Precision 650 User Manual
Page 10
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Dell Precision Workstation 620 Computer
NOTE: Precision Workstation 620 computers do not have an event log.
Fan Failure
Boot Message (F1/F2)
AGP card-cage fan
During
boot
No message
Run time
No message
CPU fan
During
boot
Alert! CPU fan not detected
Run time
On next boot: Alert! Previous system fan failure
CPU 0
During
NOTE: The computer will shut down if this issue is not resolved within about 1
Overtemp
boot
minute.
On next boot: Alert! Previous shutdown due to thermal event
CPU 1
During
NOTE: The computer will shut down if this issue is not resolved within about 1
Overtemp
boot
minute
On next boot: Alert! Previous temperature failure at Processor 1
System
During
System immediately shuts down!
Thermtrip
boot
On next boot: Alert! Previous shutdown due to thermal event
Run time
System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
Power supply fan 1
During
boot
Alert! Power supply fan failure
Run time
On next boot: Alert! previous power supply fan failure
Power supply fan 2
During
boot
Alert! Power supply fan failure
Run time
On next boot: Alert! Previous power supply fan failure
System fan (memory riser
During
Alert! System fan not detected
fan)
boot
Run time
On next boot: Alert! Previous system fan failure
PN D0744 — CPU/system fan (service kit to replace fan, not the bracket, which can
be reused.)