Zippy R2U-6300F(LH) User Manual
Page 18
1503/09/02
Attach all the remaining power supply connections to the
various peripherals as needed, these connectors are “keyed”, so
there will be only one possible way to connect them.
Before applying power to the system, make sure there are no
loose or incorrect connectors. You do not need to worry about
the setting of AC Input because of the units’ full range or auto
voltage selecting features. Double check that all connections to
the M/B are matched properly. May be you would like to test the
reduncancy function before you put back the cover of your
system chassis. Turn on (Remote on ) the on/off switch, you will
notice that if the power unit is operating properly, then
individual LEDs, external warning LEDs ( please refer to Sec.
1.11 for detail explanation) are lit Green, now remove one of the
power modules, the warning buzzer in the power system will
sound and the external warning LED which display the status of
the total power supply system will change color to be Red, the
individual LEDs (both on the rear side or on the front control
panel) indicating the power supply’s status will not light.
Meanwhile, the power supply will continue to backup the power
program files/Manual/R2U