INPUT CHARACTERISTICS:

P2U-6300P/6320P

VOLTAGE: 90 ~ 264 VAC FULL RANGE

FREQUENCY : 47 ~ 63 HZ

INPUT CURRENT: 6.0 A ( RMS ) FOR 115VAC

3.0 A ( RMS ) FOR 230VAC

INRUSH CURRENT: 60.0A MAX. FOR 115 VAC

80.0A MAX. FOR 230 VAC

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN. [A]

MAX. [A]

LOAD

LINE

5V 3.0 35 ± 5%

±

1%

80mV

12V 2.0 16 ± 8%

±

1%

120mV

-5V 0.05 0.5 ±10%

±

1%

120mV

-12V

0.05

1.0

-10%~+10%

±

1%

150mV

3.3V 1.0 20

±

5%

±

1%

70mV

+5VSB 0.1

1.5

±

5%

±

1%

60mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

SPECIFICATION:

TEMPERATURE RANGE: OPERATING 0

--- 40

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND

INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND

EFFICIENCY: 63% TYPICAL

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

OVER LOAD PROTECTION: 130 +/- 20%
OVER VOLTAGE PROTECTION: +5V

5.5V ~ 7V, 3.3V

4.0 ~ 4.5V

SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL
DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.

3.3V / 5V REMOTE SENSING

COOLING: TWO 60mm DC FANS

DIMENSION: 200 (D) x 100 (W) x 70 (H) mm

MEET IEC-1000-3-2 CLASS D