INPUT CHARACTERISTICS:
P2U-6300P/6320P
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 6.0 A ( RMS ) FOR 115VAC
3.0 A ( RMS ) FOR 230VAC
INRUSH CURRENT: 60.0A MAX. FOR 115 VAC
80.0A MAX. FOR 230 VAC
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN. [A]
MAX. [A]
LOAD
LINE
5V 3.0 35 ± 5%
±
1%
80mV
12V 2.0 16 ± 8%
±
1%
120mV
-5V 0.05 0.5 ±10%
±
1%
120mV
-12V
0.05
1.0
-10%~+10%
±
1%
150mV
3.3V 1.0 20
±
5%
±
1%
70mV
+5VSB 0.1
1.5
±
5%
±
1%
60mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
SPECIFICATION:
TEMPERATURE RANGE: OPERATING 0
--- 40
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
EFFICIENCY: 63% TYPICAL
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 130 +/- 20%
OVER VOLTAGE PROTECTION: +5V
5.5V ~ 7V, 3.3V
4.0 ~ 4.5V
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL
DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
3.3V / 5V REMOTE SENSING
COOLING: TWO 60mm DC FANS
DIMENSION: 200 (D) x 100 (W) x 70 (H) mm
MEET IEC-1000-3-2 CLASS D
Revision: A02