Output characteristics – Zippy PSL-6701P User Manual
Page 9
–
–
HG2, HP2, PSM and PSL
Ver. 1.0
9
14
INPUT CHARACTERISTICS:
HP2-6460P/6500P
VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 8.0 A FOR 115 VAC, 4.0 A FOR 230 VAC.
INRUSH CURRENT: 65 A MAX. FOR 115 VAC, 125 A MAX. FOR 230 VAC.
OUTPUT CHARACTERISTICS:
O U T P U T C U R R E N T
R E G U LA T IO N
O U T P U T
M IN .[A] M A X .[A]
LO A D
LIN E
5V
2.5
40
±
5%
±
1%
60m V
12V
1.0
27~32
±
5%
±
1%
100m V
-5V
0
0.8
±
5%
±
1%
100m V
-12V
0
1.0
±
5%
±
1%
100m V
3.3V
1.0
30
+5, -5%
±
1%
60m V
+5V S B
0.1
2
±
5%
±
1%
60m V
O U T P U T
V O LT A G E
R IP PLE & N O IS E
M A X . [P -P ]
REMARK:
TOTAL OUTPUT SHOULD NOT EXCEED 460W/500W FOR HP2-6460P/6500P.
*** WHEN PERFORMING CROSS REGULATION TEST, IT IS REQUESTED TO SET THE HIGHER OUTPUT
CHANNEL AT 90% MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20% MININUM OF RATED
SPEC.
TEMPERATURE RANGE: OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 70
0
C.
HUMIDITY: 10 ~ 90 % RH.
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE.
DIELECTRIC WITHSTAND:
INPUT / OUTPUT 1500 VAC FOR 1 MINUTE,
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE.
EFFICIENCY: 71% TYPICAL, AT FULL LOAD, 115VAC.
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 110 ~ 150% MAX.
OVER CURRENT PROTECTION:
+5V
44 A ~ 60 A, + 3.3V
33 A ~ 45 A, 12V
35.2 A ~ 48.0 A.
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.5V, 3.3V
3.9 ~ 4.3V, 12V
13.6 ~ 15V.
EMI: MEET FCC CLASS B, CISPR22 CLASS B.
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950.
REMOTE ON / OFF CONTROL.
SHORT CIRCUIT PROTECTION: SHUTDOWN AND LATCH.
BUILT-IN ACTIVE POWER FACTOR CORRECTOR.
DIMENSION: 86(H) X 150(W) X 140 (D) mm (PS/2).
COOLING: ONE 80 mm DC BALL BEARING FAN.