Hg2 remote-off i/o hg2, Output characteristics, Specification – Zippy PSL-6701P User Manual
Page 8
–
–
HG2, HP2, PSM and PSL
Ver. 1.0
HG2
remote-off
I/O
HG2
8
14
INPUT CHARACTERISTICS:
HG2-6300/6350/6400P
VOLTAGE: 90 ~ 240 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 HZ.
INPUT CURRENT: 6/7/8.0 A (RMS) FOR 115VAC, 3/3.5/4.0 A (RMS) FOR 230VAC.
INRUSH CURRENT: 65A MAX. FOR 115 VAC, 125A MAX. FOR 230 VAC.
OUTPUT CHARACTERISTICS:
O U T P U T C U R R E N T (A )
R E G U L A T IO N
O U T P U T
M IN .
M A X .
P E A K
L O A D
L IN E
5 V
3
3 5
±
5 %
±
1 %
5 0 m V
1 2 V 2
2 2 /2 6 /3 0
+ 7 % /-5 %
±
1 %
1 2 0 m V
-5 V
0
0 .8
±
5 %
±
1 %
1 5 0 m V
-1 2 V
0
1 .0
±
5 %
±
1 %
1 5 0 m V
3 .3 V
1
2 5
±
5 %
±
1 %
5 0 m V
+ 5 V S B
0 .1
2
±
5 %
±
1 %
5 0 m V
O U T P U T
V O L T A G E
R IP P L E & N O IS E
M A X . [P -P ]
REMARK (
S)
: OUTPUT CURRENT OF 5V & 3.3V COMBINED SHOULD NOT EXCEED 45A.
SPECIFICATION:
TEMPERATURE RANGE: OPERATING 0
--- 40
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE.
DIELECTRIC WITHSTAND:
INPUT / OUTPUT 1500 VAC FOR 1 SECOND.
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND.
EFFICIENCY: 68% TYPICAL.
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.
OVER LOAD PROTECTION: 130 +/- 20%.
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.5V, 3.3V
3.9 ~ 4.3V, 12V
13.6 ~ 15V.
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V.
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B.
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950.
REMOTE ON / OFF CONTROL.
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL
OUTPUT VOLTAGES (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUT VOLTAGES WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUT VOLTAGES WERE DISABLE.
3.3V / 5V REMOTE SENSING.
COOLING: ONE 80mm DC BALL BEARING FAN.
DIMENSION: 140 (D) x150 (W) x 86 (H) mm (PS/2).
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D.
ADVANCED THERMAL & ACOUSTICS CONTROL FEATURES.