Installer’s instructions – Wine-Mate SSDWC Series User Manual
Page 16

- 15 -
Installer’s Instructions
Federal law requires that WINE-MATE split cooling systems be
installed by an EPA certified refrigeration technician.
1. General Instructions
 
WINE-MATE split system is shipped as components and is ready for use only 
after a certified refrigeration technician has properly installed the system. Proper 
installation is critical. Vinotemp can only warrant the quality of the components. 
The installation and proper operation of the system must be warranted by the 
installer. Installation of the system must be done in accordance with all state and 
local building and electrical codes. 
The condensing unit and evaporator unit are connected by a liquid line and an 
insulated suction line that are supplied by the installer. These lines must be 
properly sized for the distance between the two units. After the units and lines 
are connected, the system must be checked for restriction, pressurization and 
leak. Then the system must be evacuate and charged with refrigerant. 
Refrigerant amount will vary depending on the length of line set. 
 
Parts included: 
 
Evaporator Unit (liquid line solenoid valve and expansion valve installed) 
Condensing Unit (pressure control, water regulation valve, discharge and suction 
valves and installed) 
Liquid Filter 
Liquid Indicator 
Temperature Controller (4.5”LX4.5”WX3.75”D) + Air Probe 
 
Parts not included: 
 
Liquid line copper tubing 
Suction line copper tubing 
Water lines 