Electrical connections
All of the pedestal’s main external ports are located on the power box at the South side of the
base (see Fig. 1 and Fig. 3). Additional system configuration ports are located on the control box
at the North side of the base (see Fig. 2).
Power sockets
External mains power is connected to the power input connector [35].
The pedestal also has two power output sockets [31, 32].
•
The Head power output socket [31] supplies power to a Fusion head (for more
information consult the relevant Operators Guide). This socket is controlled by the
pedestal, it is switched [28], fused and isolated on activation of an emergency stop.
NOTE:
The Schrader valve cap forms a primary pressure seal. Always replace
the cap and secure.
WARNING! It is recommended to use a residual current device (RCD) to protect
personnel should the power cable become damaged.
WARNING!
1. DO NOT plug moving devices into the auxiliary (Aux ) power port.
2. This port cannot be switched off at the pedestal and is not affected by an
emergency stop. Devices plugged into the auxiliary port must have an
independent isolator switch.