7. CODES FOR THE 1200 LOFT


Code

Description

Solution

E1

Temperature in upper zone is 4 degrees higher

than lower zone

E1 will usually disappear within an hour

when system equalizes

F1

If evaporator temperature lower than 0°F then

compressor stops and in defrost mode

Wait for three hours and check again

once temperature above 39°F alarm

disappears

F2

If compressor runs for 8 hours continuously then

unit enters defrost and compressor turns off for

20 minutes

Reset by unplugging unit if F2 alarm

persists

C1

Upper zone sensor has an open circuit and is

not functioning

– Compressor stops running.

Socket/plug on circuit board marked “UP”

has poor connection - Repair. Damaged

sensor or control board

– Repair or

replace.

C2

Lower zone sensor has an open circuit and is

not functioning

– Compressor stops running.

Socket/plug on circuit board marked
“DOWN” has poor connection - Repair.

Damaged sensor or control board

Repair or replace.

C3

Evaporator sensor has an open circuit and is not

functioning

– Compressor stops running.

Socket/plug on circuit board marked
“PTC” has poor connection - Repair.

Damaged sensor or control board

Repair or replace.

U1

Upper zone sensor has a short in the line and is

not functioning

– Compressor stops running.

Replace sensor connected to circuit
board plug marked “UP”. Repair or

replace control board.

U2

Lower zone sensor has a short in the line and is

not functioning

– Compressor stops running.

Replace sensor connected to circuit
board plug marked “DOWN”. Repair or

replace control board.

U3

Evaporator sensor has a short in the line and is

not functioning

– Compressor stops running.

Replace sensor connected to circuit
board plug marked “PTC”. Repair or

replace control board.

Alarm

sounds

If buzzer sounds temperature is lower than 32°F

or higher than 69°F.

If persists, contact dealer.