Elimination of defects, Technical data – Vetter Oil water debris aspirator User Manual
Page 7
Page 7/15
6.
Elimination of defects
Defect
Cause
Remedy
Suction motor
does not run
Protector switch has cut
off
Reactivate protector.
Call specialist if it switches off again.
No voltage at the mains
Check socket
Connection cable defec-
tive
Exchange cable*
Motor defective
Exchange motor*
Suction motor runs
but equipment
does not suction
Float ball has closed the
suction opening
Switch off motor, release float ball
Suction line is blocked
Clean suction line
Motor head turbine is
defective
Carry out maintenance*
Suction motor
runs but suction
power too low
Equipment draws outside
air
Check the adapter and motor head
for correct seating
Sealing is defective
Change sealing
Suction line is blocked
Clean suction line
Suction height is too large Position equipment to suction height
*only by a qualified electrician
Should the defect remain despite the above information then contact an authorized representative or Vetter GmbH.
7.
Technical data
Set Oil-Water-Debris Aspirator Art.Nr.: 2200000804
Unit
Data
Suction power (air)
l/min.
3,030
cu.ft./min.
107
Suction power (water)
l/min.
160
cu.ft./min.
5.7
Vacuum pressure
mm WS
2,392
psi
3.5
Current consumption of motor head
Amps
4.6
Power consumption of motor head
Watts
1,000
Voltage of motor head
V/Hz
240/50/60
Capacity of container
l
100
cu.ft.
3.53
Dimensions of aspirator base equipment
(LxWxH)
cm
86 x Ø 62
inch
34 x Ø 25
Weight (set for base equipment), ca.
kg
30
lbs
66
Noise level
dBA
84.4
Protection class : I
Protection category : IP 44
All rights reserved for technical changes within the scope of product improvement.