Chemical resistance list Products made of fibreglass-reinforced polyester
Vetter GmbH
A Unit of IDEX Corporation
Blatzheimer Str. 10 - 12
D-53909 Zülpich
Germany
Tel.: +49 (0) 22 52 / 30 08-0
Fax: +49 (0) 22 52 / 30 08-590
Mail: [email protected]
www.vetter.de
Medium
GRP
Triphenylmethane 21
Turpentine
B
Turpentine oil
B
Ucon-Hydrolube z 75 CP
Univis J 43 (Esso)
Univol 42 (Esso)
Ursa oil P 20
Vacra-Heary oil
Vacuoline BB
Vegetable oil
A
Venegar
B
Waste-water
A
Water (ocean water)
A
Water peroxide
A
Water up to 100 degrees C.
C
Water up to 80 degrees C.
C
Water, dist. 50 degrees C.
B
Water; cold
A
Wood oil
B
Wool grease
Wüf 265
Wyrol H-40
Xylene
B
Zinc salts
A
The information is based on laboratory examinations,
empirical values and is influenced by variable factors
such as the temperature, intensity and the contact
time. Exposure time 7 days
This resistance list was compiled based on the above
aspects. The information corresponds to today‘s state
of our knowledge and should be taken as typical va-
lues.
Chemical resistance
A
High resistance
B
Resistant
C
Limited resistance
D
Unstable or highly emollient
Not tested
Experiences are available on the following media (each at room temperature unless stated otherwise):