Vetter Rescue paths User Manual
Page 4

Vetter Rescue path 0.5 bar NGP
Page 3/6
3.
Preparing the product for use
3.1 Preparations for use
Only Rescue paths in perfect condition and fitted with original
Vetter inflation fittings are to be used.
4.
Operating instructions
4.1 Inflation
Open the packing bag and remove the Rescue Path. Lay out the
Rescue Path in the intended direction which is to be free of any
obstacles.
Press the connection nipple of the inflation hose for the Rescue
Path (Item no.: 1530 0034 01) into the coupling on the inflation
connection.
Check to see if the O-ring is available in the connection
before connecting the compressed air bottle.
Securely connect the hand connection of the inflation hose onto
the valve on the bottle. Open the valve on the bottle. The Rescue
Path rolls out.
The integrated safety valve, 0.5 bar, avoids inflation in excess of 0.5
bar. Immediately close the valve on the bottle if, during inflation,
you hear the safety valve blowing out.
Before use, it is necessary to disconnect the inflation device from
the Rescue Path. To do this, pull back the ring sleeve of the cou-
pling and withdraw the hose out of the coupling. A check valve in
the Path connection stops any loss of air.
Danger of tearing! Wear protection gloves!
4.2 Deflation by using the draining valve
The air can be drained by pressing the star-shaped draining valve.
The draining valve is locked into the open position by turning it
clockwise.