beautypg.com

Ignition and start up, Set the controls to automatic mode operation – Thetford 2117 Series Installation Manual User Manual

Page 19

background image

Installation Manual 19

Ignition and Start Up

Before ignition or start up of the refrigerator:

- Make sure the air flow in the lower intake vent, through the refrigerator coils and condenser, and out the upper exhaust vent is not

blocked or decreased.

- Make sure there are no combustible materials in or around the refrigerator.

NOTE: If the gas does not ignite in 30 seconds, the gas safety valve of the refrigerator automatically closes. The controls either

select a different energy source or “no” “FL” appears in the center display and you will hear an alarm sound. This means
that the gas did not ignite.

If the gas does not ignite after several attempts, refer to the
“Fault Codes” section of this manual.

Set the controls to automatic mode operation:

- Push the ON / OFF button [30] to turn the refrigerator on

(See Art01809 and Art01811).

- Push and hold the MODE button [31] until a red triangle

shows under the mode symbol and then release.

- If 120 volts AC is available to the refrigerator:

- A second red triangle shows under the

electric plug part of the mode indicator [186].

- This means that the refrigerator is operating

on AC electric.

- If 120 volts AC is not available to the refrigerator:

- A second red triangle shows under the gas

flame part of the mode indicator [186].

- This means that the refrigerator is operating

on propane gas.

- If neither 120 volts AC nor propane gas is available to the refrigerator:

- The fault codes “no” “AC” and then “no” “FL” show in the center display [33] of the LCD and an audible alarm sounds.

If an energy source is available to the refrigerator, but is not operating correctly:

- A fault code shows in the center display [33].

- The refrigerator controls try to change to a less efficient energy source.

- If a less efficient energy source is not available:

- An audible alarm starts.

- A fault code shows in the center display.

- Refer to the “Fault Codes” section of this manual.

Art01809

30

31

107

32

184

Art01811

185

186

187

33